- 19 -
FP120D,FP145D
(1)
Press this button is an emergency or when you for some other reason want to stop the machine
quickly. Pressing the emergency stop push-button stops all machine functions.
The button is released by turning it clockwise (as indicated by the arrow). After an emergency
stop, go on working in manual mode. Open the dies to the set retraction position, after which
you can continue in the normal way if the machine is otherwise in working order.
ENERGENCY STOP
(2)
Press to start electric motor and control unit.
START
(3)
This button is used to stop the machine in a normal situation. It stops both the control and the
motor.
STOP
(4)
MODE SELECTOR
MANUAL: Master dies can be opened by pressing retraction button (4) and
Closed by pressing awaging button (5). Manual mode is used when
changing dies and adjusting settings.
SEMI-AUTOMATIC: Swaging movement get started when the semi-automatic swaging
button (3) is pressed. The movement can be interrupted by releasing
the by releasing the button. If need be, dies can be opened by
using retraction button(4). Swaging goes on when the button is
repressed. After reaching the swaging diameter, dies return to the
retraction position of whether the button is pressed or not.
Control panel
CE Instruction Manual
(5)
(2)
(3)
(7)
(8)
(9)
(11)
(4)
(10)
(6)
(1)
AUTO
FOOT PEDAL
www.samway.com