- 20 -
FP120D,FP145D
(5)
SEMI-AUTOMATIC:
Swaging movement get started when the semi-automatic swaging
button (3) is pressed. The movement can be interrupted by releasing the by releasing the botton.
If need be, dies can be opened by using retraction button (4). Swaging goes on when the button
is repressed. After reaching the swaging diameter, dies return to the retraction position of
whether the button is pressed or not
(6)
The dies will open when this button is pressed. The dies open until the button is released or the
set retraction diameter has been reached. When using this button, manual mode must be
selected.
RETRACTION BUTTON:
(7)
The dies will close when this button is pressed. The dies move until the button is released or the
set swaging diameter has been reached. When using this button, manual mode must be
selected. When the machine is started with the mode selector in manual mode, swaging cannot
be started using the swaging button before first selecting O-position or opening dies with
retraction button (4). Dies will not open if they are already in the set retraction position.
SWAGING BUTTON:
(8)
SWAGING VALUE
(9)
OPENING VALUE
(10)
SWAGING CONTROL
(11)
OPENING CONTROL
AUTOMATIC: Swaging starts when the fitting is pressed against the stop device. The movement
stops if stop device is not adequately pressed by fitting. It can also be stopped by
withdrawing the fitting from the stop device before it is gripped by dies. If need be,
dies can be opened by using retraction button (4). Swaging goes on when the fitting
is repressed against the stop device. After reaching the swaging diameter, dies return
to the retraction position irrespective of whether the fitting is pressed against the stop
device or not.
CE Instruction Manual
www.samway.com