- 25 -
FP120D,FP145D
Automatic mode is best suited for serial production.
Pressing the fitting against the device starts the swaging
movement.
(1) Select MANUAL MODE.
(2) Insert the fitting 2 between the dies 1 to the correct position as shown in the figure.
(3) Swage the dies lightly until they hold the fitting properly.
(4) Loosen the locking lever 3 and push the stop device 4
against the fitting so that the spring-loaded stop device
is compressed, making the limit switch inside it actuate.
Tighten the locking lever.
(5) Open the dies until the fitting lossens.
(6) Set the required swaging diameter.
(7) Select AUTOMATIC MODE.
(8) When the stop device is pressed, the machine performs a swage and returns to the set retraction.
(9) The movement stops if the fittings is not adequately pressed against the stop device. If need be,
dies can then be opened by using the reaction button.
(10) After dies have gripped the fittings. the swaging movement can be stopped only by the
emergency stop push-button.
(11) Make sure that there are no foreign objects between the dies.
(12) Make a test swage by pressing the fitting against the stop device.
(13) Check the swaging diameter and correct the position of the stop device if necessary.
To protect your hands from getting swaged, don’t ever touch the stop device
!
AUTOMATIC MODE
In FOOT PEDAL mode dies will move as long as the pedal is pressed or till the set swaging diameter
has been reached. The swaging movement can be interrupted by lifting the foot from the pedal. If
need be, dies can opeded by using the retraction button.
(1) Lubricate the master dies and sliding plates daily with pressed-proof grease like Molub Alloy
OG-H or equivalent.
(2) Close tha master dies loosely before lubricating them.
(3) Grease (1) master dies through 6 grease nipples and (2) sliding plates through 2 nipples.
(4) Lubricate often with a small anount of grease rather than seldom with much grease.
(5) Due to metal scurt that loosens from the fittings to be swaged, the master dies are to be cleaned
carefully at intervals of approx 500 operation hours.
FOOT PEDAL
CE Instruction Manual
FOOT PEDAL
AUTO
www.samway.com