Automatic Upgrade does not Work on AP
When attempting a CAPWAP connection, if the firmware version of the AP registered with
the APC is different from the firmware version the AP is actually running, the AP is
automatically upgraded.
Symptoms
Automatic Upgrade does not Work on AP.
Version information of ‘Default’ Type checked with ‘show ap upgrade summary’ must be
the same as the firmware version of the AP.
Firmware version information of the AP can be checked under Version (current) of the
AP_ID executing the ‘show ap upgrade list’.
If the AP model is ‘WEA30x’, the ‘weafama’ package is used and if the AP model is
‘WEA40x’, the ‘weafamb’ package is used.
WEC8500# show ap upgrade summary
===== ap upgrade config summary =====
Type : Default
Mode : FTP
Path : package/ap
IpAddress : 10.10.10.11
PortNum : 21
MAXretries : 3
MAXdownload : 3
currentDownload : 0
waitApCount : 0
Target : All
PKG_Name Version FileName
Type
weafama 1.2.6.R weafama_1.2.6.R.bin Default
weafama Quick Upgrade
weafama Predownload
weafamb Default
weafamb Quick Upgrade
weafamb
Predownload
WEC8500# show ap upgrade list
/* (RC/FR/RC) : RetryCount/FailReason/RebootCause
/* Pri : VersionPriority (MD-model,A-AP config)
AP_ID Model Version(config/current) Status(RC/FR/RC) Pri force
1 WEA303i Global/ 1.2.6.R None( 0/ 0/128) MD No