1.5 Device-related Alarms
1.5.1
System Temperature Alarm
The ‘System Temperature Alarm’ is generated when the system temperature exceeds the
threshold. The alarm is cleared when the temperature drops below the threshold.
If the system temperature reaches the shutdown temperature, the system is powered off for
system protection.
Symptoms
The following alarms are generated.
*2012-08-28 12:54:46 #system-CRT: System Temperature Alarm APC Declare
Temperature(94) Threshold(93)
Possible Causes
The system’s ambient temperature has increased or the system temperature has
increased due to an external environment problem.
The temperature sensor or the fan of the system is faulty.
Solutions
If ‘System Temperature Alarm’ occurs, check the system temperature and the fan status.
1) Check the system temperature.
WEC8500# show system temp
Sensor Location Temperature
--------------- -----------
CPU sensor 1
34
CPU sensor 2
41
Board
32
2) Check the fan status of the system.
WEC8500# show system info
-----------------------------------------------------
Item System Info
-----------------------------------------------------
System Info :
model type WEC8500
system description
Samsung AP Controller
board version 0.1
cpld version 0.5
system mac address 00:7e:37:00:1e:70
system total memory 16046580 KBytes
system total disk
13520032 KBytes