WEC8500/8050 Maintenance Manual
Version 5.1
Samsung Electronics America
page 32 of 87
1.6 SNMP
1.6.1
No SNMP response
There is no SNMP response from the APC if the Simple Network Management Protocol
(SNMP) community settings are incorrect or the network is not connected.
Symptoms
When an SNMP get or set request is sent from the Management Information Base (MIB)
browser, a timeout occurs.
Possible Causes
SNMP community is not setup.
The SNMP community server (or PC) and the APC are not connected to the network.
Solutions
1) Check that the SNMP community setting of the MIB browser and the SNMP
community information of the APC match each other. If SNMP community is not
setup or the information does not match, execute the ‘snmp community’ command to
setup SNMP community
WEC8500# show snmp community
Count CommunityName AccessType IPAddress Netmask
+-----+----------------+-----------+--------------------+-------+
1 public Read Only 0.0.0.0 0
If a problem occurs on SNMP set requests, also check that ‘AccessType’ is set to
‘Read Write’.
2) Execute the ‘ping’ command on the APC to check the network connection.
If the command fails, contact your network administrator.