62
Contact class Voltage at COIL ends Contact ends judgement
3 Contact
RELAY
About DC 12V
(Operation
condition)
About DC 0V
(Stop condition)
CLOSE between C and NO
OPEN between C and NC
OPEN between C and NO
CLOSE between C and NC
2 Contact
RELAY
About DC 12V
About DC 0V
CLOSE
OPEN
12. References
Reference No. 1) Connection diagram of CABINET-DOOR
Reference No. 2) Check of RELAY
At first, disconnect the housing connected
to the LOAD connector (MAIN PCB CN70,
71, 72) and then check and measure the
following things.
1. Measure the voltage of COIL ends to check
operation.
2. Measure the resistance of Contact ends to
check ON/OFF.
3. If Contacts does not operate as described
in the above table, replace the relevant
RELAY.
Example
) C COMMON, NC NORMAL CLOSE,
NO NORMAL OPEN
3 contact
COIL ends
< RELAY Movable contact (make) >
COIL ends
2 contact
Measure after
disassembly
Connection at Hinge-Upp of the Freezer
Black
Brown
Red
Orange
Yellow
Pink
Blue
Violet
Gray
White
Light-Blue
Black
Brown
Red
Orange
Yellow
Pink
Blue
Violet
Gray
White
Light-Blue