Change of NOTCH GAP of Freezer
(ÒCOLDERÓ on the basis of ÒMEDIUMÓ)
Change of NOTCH GAP of Freezer
(ÒWARMERÓ on the basis of ÒMEDIUMÓ)
Temperature compensation when the
ambient temperature is below 17 .
Temperature
change
- 0.5
- 1.0
+ 0.5
No compensation
D612
D611
Relevant DIODE No. used
Change of NOTCH GAP of Refrigerator
(ÒCOLDERÓ on the basis of ÒMEDIUMÓ)
GAP change
4.0
3.0
5.0
2.0
D618
D617
Relevant DIODE No. used
Change of NOTCH GAP of Refrigerator
(ÒWARMERÓ on the basis of ÒMEDIUMÓ)
GAP change
3.0
2.0
4.0
5.0
D620
D619
Relevant DIODE No. used
GAP change
2.0
3.0
4.0
5.0
D614
D613
Relevant DIODE No. used
GAP change
4.0
2.0
3.0
5.0
D616
D615
Relevant DIODE No. used
Notice
Although there are more OPTIONs except the
above things described, they are not required on
A/S with regard to the function of refrigerator
regulation and so, not described here.
The above things are only the functions related
with the temperature change actually used.
Control of water supply to ICE-MAKER (Change of SOLENOID opening time)
use DIP S/W
FTA / DTA
S/W 1
S/W 2
S/W 3
6 sec
OFF
OFF
OFF
5 sec
ON
OFF
OFF
7 sec
OFF
ON
OFF
8 sec
ON
ON
OFF
9 sec
OFF
OFF
ON
12 sec
ON
OFF
ON
15 sec
OFF
ON
ON
23 sec
ON
ON
ON
The refrigerator is released with all S/W1 ~ S/W3 OFF (water supplying time is 7 seconds).