Temperature Change of Ice-Making SENSOR for Eject operation
Classification
D635
D636
D637
-10
0
0
0
-11
1
0
0
-12
0
1
0
-13
1
1
0
-14
0
0
1
-9
1
0
1
-8
0
1
1
-7
1
1
1
MODEL OPTION function
This refrigerator can operate 2 MODEL using one MAIN PCB AssÕy. So, since function of PANEL PCB
and MAIN performance function are to be selected to change by MODEL OPTION of MAIN PCB, the
same specification of PCB should be used on replacement of PCB or the following specification of
MODEL OPTION and H/W OPTION should be applied. On change of MODEL OPTION, POWER
should be OFF and ON for normal operation.
<Table for PCB specification>
SR-S25/26NTA
H.M-CYCLE
(Basic)
MO-1,
MO-2
Not used
ICE MAKER OPTION part = not used
C901 ~ C905(104)=JUMP WIRE used
RY74, RY76 = not used
Water supply control DIP S/W = not used
SR-S24/25/27FTA
SR-S24/25/
(DTA)
H.M-CYCLE
+
ICE &
WATER
DISPENSER
+
HOME BAR
(WITHOUT
HOMEBAR)
Only MO-2
used
ICE MAKER OPTION part = used (refer
to the following information)
C901 ~ C907 = 104 AXIAL
C/CAPACITOR used
R901 = 12 used
R902,906,907,908 = 1.0 - J used
R903,905 = 10 - J used
R904 = 10 - F used (deviation 1%)
R909,910,911=4.7 - J used
CN90=8P CONNECTOR SMW250-08
used
Water supply control DIP S/W used
D638, 639, 640 used (necessary on the used
of DIP S/W)
MODEL
SET function
H/W OPTION specification on PCB
Remark
Notice
When PCB should be replaced, check the specification described in the above TABLE and use the
regular specification of PCB for normal operation. If possible, avoid remodeling because
function resulted from the change of SPEC may occur.
Information
See the PCB circuit diagram of this manual.
MODEL OPTION
on PCB