10-4) Trouble with self-diagnosis
(1) Trouble with ambient thermal-sensor
MAIN-PCB
connector (CN32) is normally
inserted?
START
Repair of connector
contact trouble
Ambient thermal-sensor
port is normal?
Replacement of thermal-
sensor
MICOM PIN#60 voltage
input is normal?
Check of MAIN-PCB cold
lead and short
No trouble with PCB and thermal-sensor.
Re-check of connector
contact trouble.
N
N
Y
Y
N
Y
(2) Trouble with thermal-sensor for refrigerator
Thermal-sensor
port is normal?
START
Replacement of
thermal-sensor
MAIN-PCB connector (CN31)
is normally inserted?
Repair of connector contact
trouble, Re-insertion
Wire-Connection
between MAIN-PCB connector(CN31)
sensors is normal?
Snapping of wire between
connector and sensor,
CHECK and Repair
No trouble with PCB and
thermal-sensor. Re-check of
connector contact trouble.
N
N
Y
Y
N
Check of cold lead, short,
lead Touch
N
Y
MICOM PIN#56 voltage
input is normal?
Y
41