(3) Trouble with defrost-sensor for refrigerator (Bimetal)
MAIN-PCB
connector (CN31) is normally
inserted?
START
Repair of connector (CN31)
contact trouble, Re-insertion
Replacement of
thermal-sensor
Repair of non-insertion of
connector and contact trouble
Defrost-sensor port
is normal?
Connection
between Defrost-sensor and
Connector is normal?
No trouble with PCB and
thermal-sensor.
Re-check of connector contact trouble.
N
N
Y
Y
N
Y
Check of cold lead, short,
lead Touch
MICOM PIN#57
voltage input is normal?
N
Y
(4) Trouble with thermal-sensor for freezer
MAIN-PCB
connector (CN30) is normally
inserted?
START
Repair of connector (CN30)
contact trouble, Re-insertion
Thermal-sensor
port for freezer
is normal?
Replacement of
thermal-sensor
Connection between
sensor of the freezing room and
connector is normal?
Repair of connector contact
trouble, Re-insertion
No trouble with PCB and
thermal-sensor.
Re-check of connector contact trouble.
N
N
Y
Y
N
Check of cold lead,
short, lead Touch
N
Y
MICOM PIN#58 voltage
input is normal?
Y
42