4. Alignment and Troubleshooting
Depth 1
Depth 2
Depth 3
Depth 4
All Report
Protocol
Supplies Info
Configuration
Error Info
Usage Counter
Component Check
Report
Fax Options
NVM Initialize
NVM Read Write
NOTE
Refer to NVM Read Write table.
EDC Mode
Test Routine
NOTE
Refer to Test Routine.
c) Data Setup
•
Send Level
You can set the level of the transmission signal. Typically, the Tx level should be under -12 dBm.
NOTE
The Send Fax Level is set at the best condition in the shipment from factory.
•
DTMF Level
This is a setting value of the High level tone and low level tone at DTMF mode. (Not dial mode)
•
Pause Time
It shows the delay time when receiving the pause input at auto dial.
•
Dial Mode
This function can choose dial method.
* Default : Dial (Dial/Pulse)
•
Modem Speed
You can set the maximum modem speed. Communication is done with modem speed automatically set at lower speed
when communicating with a slower speed modem since communication is done on the standard of the side where
modem speed is low for transmission/reception. It is best set 33.6 Kbps as default setting.
•
Error Rate
When the error rate is about exceed the set value, the Baud rate automatically adjusts to 2400 bps. This ensures that the
error rate remains below the set value. You can select the rate between 5% and 10%.