Failure 2
When the external MOH does not work.
Troubleshooting 2
Reconnect normally
No
Change the shunt pin to ‘EXT’ position
No
Replace base board
Yes
Is connection normal?
Check if MOH source is connected
to pin 3, 4 of the P973
Is the shunt pin normal?
Yes
Refer to ‘When internal MOH/BGM
is not working’
No
Check if the shunt pin(p421) is located at
‘EXT’ position
Is internal MOH normal?
Check if internal MOH is working
Yes
END