© SAMSUNG Electronics Co., Ltd.
20
Failure 2
When the 2BRI functions but No Call is connected.
Troubleshooting 2
Abbreviation
- ISAC: ISDN Subscriber Access Controller
- DU: Data Upstream
- DD: Data Downstream
- FSC: Frame Synchronize
- OSC: Oscillator
No
Repair the address, data bus
Is the bus normal?
Yes
OK
No
Are the signals normal?
Yes
Check the address, Data bus signals
No
Is clock(7.68 MHz) normal?
Check if the 7.68 MHz clock normally
are supplied to pin35(U151, U251)
Yes
- Check the clock path.
- Replace the OSC(Y301)
Check if FSC(pin 52), 4M(pin 53),
DU(pin 50), DD(pin 51) are normally
supplied to the ISAC
Check the CPLD(U1)