3.6 Caller ID Failures
Failure
When Caller ID does not send and receive.
Troubleshooting
END
No
Check CPLD
(Complex Programmable Logic
Device)(U51) version
No
Are signals normal?
Yes
Are MMCs normal?
Check if the MMCs are set normally
Yes
Check if the signals of the U151 are
normal.(8 M pin32, INT_8MS: pin64,
HAS: pin13, MRW: pin129, MRD: pin127,
CS_DSP: 17)
Replace LV51
Repair MMC