Table of Figures
Table of Figures
[Figure 2-1: Electrical connections] .............................................................................................................. 5
[Figure 2-2: Name Plate] .................................................................................................................................. 7
[Figure 2-3: PV connections] ........................................................................................................................... 8
[Figure 2-4: Distribution box connection diagram]................................................................................. 8
[Figure 2-5: Derating Curve] ........................................................................................................................ 11
[Figure 2-6: Power efficiency curve of System] ...................................................................................... 11
[Figure 2-7: Power efficiency curve of PV Generation] ........................................................................ 12
[Figure 3-1: Part View of Samsung All in One] ....................................................................................... 15
[Figure 4-1: Front status indication screen] ............................................................................................ 16
[Figure 4-2: PV generation, battery charge, Load use, sell remaining amount] .......................... 17
[Figure 4-3: PV generation, battery discharge, Load use, buy shortage amount] ...................... 17
[Figure 4-4: PV generation, Battery standby, Load use, sell remaining amount] ........................ 17
[Figure 4-5: PV generation, Sell remaining amount] ............................................................................ 17
[Figure 4-6: PV generation, Buy shortage amount] .............................................................................. 18
[Figure 4-7: Battery discharge, Load use] ................................................................................................ 18
[Figure 4-8: Battery discharge, Load use, Buy shortage amount] .................................................... 18
[Figure 4-9: Indication screen on Standby Mode]................................................................................. 19
[Figure 4-10: Indication screen on Forced charged Mode] ................................................................ 19
[Figure 4-11: Indication screen on stand-alone mode] ....................................................................... 19
[Figure 4-12: Event occurrence, Grid RMS over current protection] ............................................... 20
[Figure 4-13: Event occurrence, DC link over voltage protection] ................................................... 20
[Figure 4-14: Event occurrence, PV string1 reverse connection protection] ................................ 20
[Figure 4-15: Event occurrence, PV string2 reverse connection protection] ................................ 20
[Figure 4-16: Event occurrence, PV string1 over voltage protection] ............................................. 21
[Figure 4-17: Event occurrence, PV string1 over current protection] ............................................. 21
[Figure 4-18: Event occurrence, PV string2 over voltage protection] ............................................. 21
[Figure 4-19: Event occurrence, PV string2 over current protection] ............................................. 21
[Figure 4-20: Event occurrence, Battery over voltage protection] .................................................. 21
[Figure 4-21: Event occurrence, Battery over current protection] ................................................... 22
[Figure 4-22: Event occurrence, On sequence Inverter DC link event] ........................................... 22
[Figure 4-23: Event occurrence, On sequence Battery V/I event] .................................................... 22
[Figure 4-24: Event occurrence, Normal Inverter DC link event] ...................................................... 22
[Figure 4-25: Event occurrence, Normal Battery V/I & BDC DC link event].................................... 22
[Figure 4-26: Event occurrence, On sequence Inverter DC link event] ........................................... 23
[Figure 4-27: Event occurrence, Normal Inverter DC link & PV I event] .......................................... 23
[Figure 4-28: Event occurrence, Temperature protection] ................................................................ 23
[Figure 4-29: Event occurrence, Over Current TZ Fault]...................................................................... 23
[Figure 4-30: Events occurrence, temperature sensor connection error] ..................................... 23
[Figure 4-31: Event occurrence, PV mis-wiring] ..................................................................................... 24
[Figure 4-32: Event occurrence, SPI communication event] ............................................................. 24
[Figure 4-33: Event occurrence, Single fault event] ............................................................................. 24
[Figure 4-34: Event occurrence, Continuously 3 times Inverter fault] ............................................ 24
[Figure 4-35: Indication screen on Application Download Mode] .................................................. 24
[Figure 4-36: Initial indication screen on power on] ............................................................................ 25
[Figure 4-37: Standby state indication screen before the EMS command] .................................. 25
[Figure 5-1: Communication terminal] ..................................................................................................... 26
[Figure 5-2: Connecting to the website] .................................................................................................. 28
iv
Australia (Eng.) 05/2015. Rev1.1