Part 1: Site Survey and Overview of DECT Systems
16
Example 2: Small overlap area
In areas where two coverage areas
meet perpendicularly (such as two
passageways), there may be an area
of very small overlap which can cause
the loss of a call. This is because you
are moving from an area with only one
Base Station to an area also with only
one Base Station. Therefore the hand-
set does not have enough time to reg-
ister to the other Base Station until you
are out of the coverage area of the first
Base Station. The problem may be
solved by moving one of the Base Sta-
tions closer to the corner point where
the two passageways meet in order to
cover both.
Example 3: No overlap
In areas where the coverage between
two Base Stations is separated by
steel doors or gates, the handset does
not have time to hand over and regis-
ter itself to the next Base Station, thus
causing the call to be dropped. This
may be solved by moving the Base
Stations closer to each other.
No overlap when steel door or
gate is closed