Part 2: DECT Hardware Installation and Programming
29
Analogue Telephone Extensions
Extensions connect to the IWUs.
D-Sub Pin
No.
Cable Colour
IWU Line
EE
14 WHITE/BLUE 0A
1 BLUE/WHITE 0B
15 WHITE/ORANGE 1A
3 ORANGE/WHITE 1B
2 RED/SLATE
0
EARTH
16 BLACK/ORANGE
1
EARTH
17 WHITE/GREEN 2A
4 GREEN/WHITE 2B
18 WHITE/BROWN 3A
6 BROWM/WHITE 3B
5 SLATE/RED
2
EARTH
19 ORANGE/BLACK
3
EARTH
20 WHITE/SLATE 4A
7 SLATE/WHITE 4B
21 RED/BLUE 5A
9 BLUE/RED 5B
8 BLACK/BLUE
4
EARTH
22 RED/BROWN
5
EARTH
23 RED/ORANGE 6A
10 ORANGE/RED 6B
24 RED/GREEN 7A
12 GREEN/RED 7B
11 BLUE/BLACK
6
EARTH
25 BROWN/RED
7
EARTH
Power Connection
Figure 2.5 Power Connection