background image

E-

59

Data Link Layer Options:

 BACnet IP, (Annex J) 

 BACnet IP, (Annex J), Foreign Device   

 ISO 8802-3, Ethernet (Clause 7)

 ANSI/ATA 878.1, 2.5 Mb. ARCNET (Clause 8)

 ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), baud rate(s)                                         

 MS/TP master (Clause 9), baud rate(s):                                                                                

 MS/TP slave (Clause 9), baud rate(s):                                                                                     

 Point-To-Point, EIA 232 (Clause 10), baud rate(s):                                                            

 Point-To-Point, modem, (Clause 10), baud rate(s):                                                         

 LonTalk, (Clause 11), medium:                                                                                                

 BACnet/ZigBee (ANNEX O)

 Other:                                                                                                                                                  

 

 

Device Address Binding:

Is static device binding supported? (This is currently necessary for two-way communication 

with MS/TP slaves and certain other devices.) 

Yes  

 No

Networking Options:

  Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, 

 Ethernet-MS/TP, etc.

 Annex H, BACnet Tunneling Router over IP 

 BACnet/IP Broadcast Management Device  (BBMD) 

    Does the BBMD support registrations by Foreign Devices? 

 Yes 

 No

    Does the BBMD support network address translation? 

 Yes 

 No

Character Sets Supported:

Indicating support for multiple character sets does not imply that they can all be supported 

simultaneously.

 ANSI X3.4 

 IBM™/Microsoft™ DBCS 

 ISO 8859-1

 ISO 10646 (UCS-2) 

 ISO 10646 (UCS-4) 

 JIS 0208

If this product is a communication gateway, describe the types of non-BACnet equipment/

networks(s) that the gateway supports:

     This gateway switches SAMSUNG air conditioner protocol to BACnet protocol to make 

RS-485 communication possible with the air conditioners connected to gateway. 

BACnet Protocol Implementation Conformance Statement (Continued)

NASAS_MIM-B17N_BACnet Gateway_IM_EN_03719A(1).indd   59

2013-04-25   오전 10:14:42

Summary of Contents for BACnet Gateway MIM-B17N

Page 1: ...NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 68 2013 04 25 오전 10 14 42 ...

Page 2: ...ateway MIM B17N Air Conditioner installation manual imagine the possibilities ThankyouforpurchasingthisSamsungproduct EN DB68 03719A 1 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 69 2013 04 25 오전 10 14 43 ...

Page 3: ...he BACnet Gateway Do not install the BACnet Gateway in a location where it will come into contact with combustible gases machine oil sulphide gas etc Avoid locations where acid alkali solution or special spray is used Choose a location that is dry and sunny but not exposed to direct sunlight Suitable temperature is between 0 C 32 F and 39 C 102 2 F Do not spill water into the BACnet Gateway Do not...

Page 4: ...the Computer Environment 15 Setting the BACnet Gateway 17 Reading EHPWatt hour Meter 22 System Setting Initialization 27 System Settings 28 Tracking 42 Device Configuration 48 BACnet Protocol Implementation Conformance Statement 56 Standard Object Types Supported 60 Detail Description of Object 61 BACnet Point List 62 Other Information 67 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 3 2013 04...

Page 5: ...interface modules must be installed in such a way that the wires can be connected to the BACnet Gateway with ease Note TheBACnetGatewayisaserverandsupportsstaticIP ToaccesstheBACnetGatewaythroughtheinternetor withBMSSystem theBACnetGatewayaddress which istheIPaddress mustbeknown AstaticIPservicefromaninternetserviceprovider mustbeusedifxDSL ADSL VDSL isbeingusedfor internetconnection StaticIPcosts...

Page 6: ... or service provider Accessories The BACnet Gateway must be installed by a trained installer Ensure the main power is turned off before installing the BACnet Gateway Be sure to use adapter and power cable we provide The power cable and the communication cable must be installed according to the national electrical wiring regulations NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 5 2013 04 25 오전 ...

Page 7: ... is supplied CPU Alive CPU operation indicator Blinks in orange with 1 second intervals during normal operation Ethernet Linked Internet connection indicator Turns green during normal connection Ethernet Active Internet data transmission reception indicator Blinks in orange during normal transmission reception COM1 5 TX Channel 1 5 OnOff controller Outdoor unit Data transmission Indicator Blinks i...

Page 8: ... Gateway error status using this terminal SD card socket Sub memory for program update and set information saving socket RS485 Communication Terminal Connect for RS485 communication with devices such as OnOff controller Outdoor unit COM1 COM5 Ethernet Terminal Connect LAN cable Cable tie groove Groove for arranging cables Cable tie groove SD Card Socket Serial Terminal Power Terminal Reset Button ...

Page 9: ...Cable Main Board Sub Board BACnet Gateway Interior Main Parts Viewing the Parts Continued Note If you need external circuit configuration consult with the manufacturer Product Dimensions NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 8 2013 04 25 오전 10 14 33 ...

Page 10: ...rthedeviceswhichsupportnewcommunication setthecommunicationchannel modeon Systemsetting Tracking menuas NEW andforSIM PIMwhichconventional communicationisapplied setthecommunicationchannelmodeas IM Youcannot connectindoor outdoorunitSETwhichconventionalcommunicationisappliedtonew communicationBACnetGateway Whensettingcommunicationchannelmodeas NEW theaddressofvirtualcentralized controlwillbeassign...

Page 11: ...l Note 1 Indoor Unit Outdoor Unit DVM S HR DVM S HP DVM MINI outdoor unit and indoor units which can be connected to DVM S HR DVM S HP DVM MINI outdoor unit 2 OnOff controller MCM A202DN 3 SIM MIM B12 Needed for EHP power distribution 4 PIM MIM B16 Needed for EHP power distribution 5 Watt hour Meter RS485 comm type Connected with SIM Needed for power distribution Please consult Samsung for compati...

Page 12: ...75 Must not exceed 15 units per each RS485 communication terminal Outdoor unit 80 Must not exceed 16 units per each RS485 communication terminal SIM PIM 8 Communication mode IM Watt hour Meter 64 Maximum 8 units can be connected to 1 SIM PIM NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 11 2013 04 25 오전 10 14 34 ...

Page 13: ...nd BACnet Gateway using 2 screws Depending on the installation environment fix BACnet Gateway using assistant holes Screws for assistant hole are not provided by our company 5 If you install BACnet Gateway inside of the wall or wiring from the rear side is needed use wiring groove on the bottom of BACnet Gateway TopreventbreakdownanddamageofBACnetGateway and forsafeusage itisrecommendedtoinstallBA...

Page 14: ... as the right figure 3 Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal Then connect outdoor unit communication cable SOL_ COM R1 R2 to the terminal block R1 A R2 B 4 Connect LAN cable to the Ethernet terminal of BACnet Gateway Then arrange it using cable tie 5 Fasten the bottom cover of BACnet Gateway and fix it using 2 screws Maximum80outdooruni...

Page 15: ...gure 3 Separate 1 terminal block from 5 terminal blocks which are attached to RS485 communication terminal Then connect SIM PIM communication cable C1 C2 to the terminal block C1 A C2 B 4 Connect LAN cable to the Ethernet terminal of BACnet Gateway Then arrange it using cable tie 5 Fasten the bottom cover of BACnet Gateway and fix it using 2 screws Maximum8SIM PIMunitscanbeconnectedtooneBACnet Gat...

Page 16: ...recommended Note AcrosscableisusedwhenconnectingtoPCdirectly Itisproducedastransmissionandreceptioncablesare crossed Cable1 2 3 and6arecrossedeachother Visitinternethomepage http www microsoft com silverlight todownloadSilverlight Oryou candownloaditthroughthedownloadlinkwhich isnoticedautomaticallywhenyouaccesstoBACnet Gatewayforthefirsttime Connect BACnet Gateway and Computer directly Connect BA...

Page 17: ...ACnet Gateway IP 192 168 0 100 To access to BACnet Gateway IP set the network information of BACnet Gateway connected computer as follows 1 Select My network Settings icon and click Properties using right button 2 Select Local area connection icon and click Properties using right button from the network connection folder 3 Internet protocol TCP IP and click Properties using right button from the l...

Page 18: ...xplorer window appears enter IP address http 192 168 0 100 on the address bar then press ENTER 3 If it is the first time to access BACnet Gateway Install Microsoft Silverlight message will appear If Microsoft Silverlight have already installed the screen will not appear ction NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 17 2013 04 25 오전 10 14 37 ...

Page 19: ...nue installation After installation access to BACnet Gateway again Silverlight operates normally with Windows XP SP2 or later version It may not operate normally with previous version of Windows 4 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 18 2013 04 25 오전 10 14 37 ...

Page 20: ...t is included in administration group Factory default BACnet Gateway ID is admin and password is ac0530 Note Onlyauthorizeduserscanaccesstowebpage Connectionspeedmayslowdown Fewerthan5concurrentusersare recommended BACnetGatewaymanagershouldchangeIDandpasswordforsecurityand management Logout Ifyouwanttologout click LOGOUT onthetopofthemenu BACnet Gatewaywillbeended If you use accounts with authori...

Page 21: ...n menu to switch to BACnet Gateway If you use accounts with authorization level lower than management group or accounts with general authorization level BACnet configuration will not be displayed on the menu If the BACnet configuration menu does not appear consult the manager 6 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 20 2013 04 25 오전 10 14 37 ...

Page 22: ...ss BACnet Gateway Device Configuration screen will appear initially If you click DMS2 Connect button screen will be switched to initial screen 7 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 21 2013 04 25 오전 10 14 37 ...

Page 23: ... for name and only available special characters are _ and space Value for CT proportion should be integer between range of 1 5000 4 Click Save CT proportion value will be saved to the BACnet Gateway If you do not click Save changed setting will not be saved 5 Watt hour meter value will display the actual value of electricity on the corresponding watt hour meter Value will be updated automatically ...

Page 24: ...line setting You can select from 1 31 If you select the last day of the month it will automatically set the last day of corresponding month as baseline Ex Last day of February 28th or 29th 4 Click Save Changed settings will be saved to the BACnet Gateway If you do not click Save changed setting will not be saved 1 2 4 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 23 2013 04 25 오전 10 14 37 ...

Page 25: ...you can enter the period in daily unit If you select monthly period setting you can select the period in monthly unit 3 Set the period If you set period in daily unit you can set up to maximum 90 days If you set period in monthly unit you can set up to maximum 1 months 4 Click Save Changed setting will be saved to BACnet Gateway If you do not click Save changed setting will not be saved 1 2 4 3 NA...

Page 26: ...ayed as 16 23 in BACnet Gateway Below table shows the channel information of the terminal which SIM and watt hour meter is connected Terminal block 1 is on the most left side in SIM PIM Channel 1 is on the most left side and 8 channels are arranged in a line 4 Check the information of indoor outdoor unit which is connected to watt hour meter 3 7 2 1 Terminalblock Location Terminalblock1 Terminalbl...

Page 27: ...it to execute power distribution If you do not set the watt hour meter information the power distribution result of the indoor unit will be displayed as 0 7 Click Save Changed setting will be saved to BACnet Gateway If you do not click Save changed setting will not be saved Information of watt hour meter connected to indoor outdoor unit should be accurate If the watt hour meter information is not ...

Page 28: ...n menu screen Caution will be displayed on LCD Display 3 Initialize BACnet Gateway by clicking Set when caution phrase appears If you press Menu button system will return to main menu without initialization When initializing system setting all saved data in BACnet Gateway will be deleted After initialization you must aware that the saved data and IP address will be reset to default factory setting...

Page 29: ...ult gateway Network No and DNS server are enabled Enter values for each item 15 letters can be entered for each item Each item should match with the network address form You can enter from 1 to 40 for Network No If you want to use multiple BACnet Gateway in the same network you should set up Network No differently 4 Click Save button on the BACnet network information section 1 2 4 3 NASAS_MIM B17N...

Page 30: ...ateway by entering the IP set and saved manually Note Factorysettingisasfollows 1 IPaddress 192 168 0 100 2 Subnetmask 255 255 255 0 3 Defaultgateway 192 168 0 1 4 DNSserver 0 0 0 0 SinceBACnetGatewaysets192 168 0 254asengineeringIPinternally itshould bealwaysavailableregardlessofcurrentIP 5 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 29 2013 04 25 오전 10 14 38 ...

Page 31: ...rom 1 to 31 Hour You can enter from 0 to 23 Minute You can enter from 0 to 59 Second You can enter from 0 to 59 4 Click Save button on the System time section 5 When the pop up window appears click OK When message with Reading data from DMS Please wait appears saving is completed Then System Settings screen appears again with all items disabled Note Systemtimereflectssetcurrentvalue 1 2 3 4 5 NASA...

Page 32: ...he Select language section 3 Select a language you want and click Save 4 When the pop up window appears click OK BACnet Gateway will restart and the system will be changed to selected language 1 2 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 31 2013 04 25 오전 10 14 38 ...

Page 33: ...Gateway name field enabled You can use maximum 30 letters including English alphabets and special symbols When BACnet Gateway name is set the name will be displayed on the top title bar of web browser 4 Click Save after setting is completed BACnet Gateway Name Setting 4 2 1 3 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 32 2013 04 25 오전 10 14 39 ...

Page 34: ...Please wait message appears and saving is completed Afterwards system environment setting screen appears again as all items are disabled You can check new BACnet Gateway name on the title bar of web browser Note NameofBACnetGatewayissettoblankasfactory default 5 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 33 2013 04 25 오전 10 14 39 ...

Page 35: ... items fields are enabled If you select Apply you should enter e mail address SMTP server ID password and SMTP server address If you select Not apply E mail ID PW and SMTP server items will not affect 4 Click Save after setting is completed Error Mail Forwarding Setting 4 2 1 3 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 34 2013 04 25 오전 10 14 39 ...

Page 36: ...a from DMS2 Please wait message appears and saving is completed Afterwards system environment setting screen appears again with all items are disabled Note Infactorysetting Notapply ischeckedanditemfields E mail ID PW SMTPserver areblank 5 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 35 2013 04 25 오전 10 14 39 ...

Page 37: ...s S NET3 S NET mini Note IftheuppercontrollerusesPublicIP youmustsetthePublicIPofuppercontroller toaccessBACnetGatewayfromthoseuppercontrollers Iftheuppercontrolleruses privateIP youmayaccessBACnetGatewayfromthoseuppercontrollerswithout settingthePublicIPofuppercontroller PrivateIPrange 10 0 0 0 10 255 255 255 172 16 0 0 172 31 255 255 192 168 0 0 192 168 255 255 Setting Public IP of upper control...

Page 38: ...l operation of indoor unit except DDC and disable remote control when inputting contact point control signal In level emergency stop status it will not be controllable even if the command is from upper controller Pattern 3 Level Operation Stop Level signal input timing It changes operation stop status of all indoor units Pattern 4 Pulse Operation Stop Disable Enable Pulse signal It changes operati...

Page 39: ...ote Contactpointcontrolpatternissettopattern1asfactorydefault For extension purpose BACnet Gateway has total of 10 DI DO ports Contact control and output function is assigned to Ch1 and Ch2 Ch3 Ch10 will be assigned to additional functions For proper contact control connect with Ch1 and Ch2 5 System Settings Continued NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 38 2013 04 25 오전 10 14 39 ...

Page 40: ...ort 1 changes from ON to OFF all indoor units will be given Stop command 3 If the contact signal of port 2 is OFF you cannot control all indoor units using remote controller 4 If the contact signal of port 2 changes from OFF to ON you can control all indoor units using remote controller 5 If the contact signal of port 2 changes from ON to OFF you cannot control all indoor units using remote contro...

Page 41: ...ternal contact signal control Pattern 4 Pulse signal control Emergency Stop Resume Operation No Connection Operation Stop A C Enable Disable remote control Operation Stop A C A C DI Digital Input Circuitry according to Control Switch Pattern System Settings Continued NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 40 2013 04 25 오전 10 14 40 ...

Page 42: ...rmation section 3 Click Edit from the BACnet gateway information section 4 If you want to initialize Recipient_list Check and click Save 5 When the pop up window appears click OK BACnet Gateway will restart and the system will initialize Recipient_list 1 3 4 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 41 2013 04 25 오전 10 14 40 ...

Page 43: ...can set name for connected device Set the names to help you recognize the location of the device easily Communication mode setting for each channel Roles It records what devices are connected to COM1 COM5 of BACnet Gateway Through tracking BACnet Gateway searches proper devices that fits to user s setting Select proper communication mode which fits to connected device What is communication mode Yo...

Page 44: ...Edit from the Communication mode by channel screen Edit button will be switched to Cancel All selection buttons will be enabled However the channels with searched device maintain its button in disabled status 1 2 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 43 2013 04 25 오전 10 14 40 ...

Page 45: ...W communication mode When IM is set as communication mode setting will allow tracking monitoring and controlling SIM PIM 4 Click Save after setting is completed If you click Cancel check boxes will be disabled and Cancel button will switch to Edit 5 When message with Reading data from DMS Please wait appears saving is completed Then System Environment Setting screen appears again with all items di...

Page 46: ...E 45 DVMTracking 1 Click Device Configuration 2 Click DVM Tracking 1 2 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 45 2013 04 25 오전 10 14 40 ...

Page 47: ... for each channel Tracking will be executed only to the channels which communication mode is set to either NEW or IM 6 Pop up window with message Tracking is in progress Please wait will appear Tracking takes from few seconds to 5 minutes However it may vary depending on the number of installed controllers 3 4 5 Tracking Continued NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 46 2013 04 25 오전 ...

Page 48: ...hannel Ifthereisnosearchedoutdoorunit OnOffcontroller SIM PIM itisregardedasDVM trackingfailure Iftherearedeviceswhichhavesameaddress firstsearcheddevicewillberegistered only Searchingorderisnotfixed ThenumberofOnOffcontrollerdoesnotcontainthenumberofvirtualcentralized controller Totalnumberofindoorunitsincludesgeneralindoorunits ERVandAHU If you execute tracking system setting will be initialized...

Page 49: ...connected devices to BACnet Gateway will be stopped when you use this function Connect searched device to the other channel and execute tracking If the other device is searched in the channel you want to use use Disconnect all devices function If you use this function BACnet Gateway device connection status will be initialized 3 4 1 2 Device Configuration NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A...

Page 50: ...from DMS Please wait appears and all the devices are disconnected page will be refreshed Note Afterexecuting Disconnectalldevicefunction devicesearchstatusofBACnet Gatewaywillbeinitialized Youshouldexecutetrackingagainafterusingdisconnectalldevicesfunction 5 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 49 2013 04 25 오전 10 14 41 ...

Page 51: ...t Edit will be changed to Cancel Note Ifyouclick Cancel button Cancel buttonwillbeswitchedto Edit buttonandthe changednameofdeviceswillberestoredtooriginalname Renaming the devices 1 Device Configuration Continued NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 50 2013 04 25 오전 10 14 41 ...

Page 52: ...ers 3 Click Save after setting is completed If you click Cancel text boxes will be disabled and the Cancel button will be switched to Edit 4 When message with Reading data from DMS Please wait appears saving is completed Then Tracking screen appears again as all items are disabled 2 3 NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 51 2013 04 25 오전 10 14 41 ...

Page 53: ...om Object ID column Detail information of the selected device will be displayed in device information Checking device information 1 Device Configuration Continued NASAS_MIM B17N_BACnet Gateway_IM_EN_03719A 1 indd 52 2013 04 25 오전 10 14 41 ...

Page 54: ...l be displayed between 3 You can enter numbers to modify the Output type objects Click Edit button on the bottom of the Device configuration screen and enter the value when the text box enables 4 Click Save after setting is completed If you click Cancel text boxes will be disabled and the Cancel button will be switched to Edit 5 When message with Reading data from DMS Please wait appears saving is...

Page 55: ...ff 7 You can select the values to modify the Output type objects Click Edit button on the bottom of the Device configuration screen and select the value from On or Off when the button enables 8 Click Save after setting is completed If you click Cancel buttons will be disabled and the Cancel button will be switched to Edit 9 When message with Reading data from DMS Please wait appears saving is comp...

Page 56: ...e Output type objects Click Edit button on the bottom of the Device configuration screen and select the value when the list box enables 12 Click Save after setting is completed If you click Cancel buttons will be disabled and the Cancel button will be switched to Edit 13 When message with Reading data from DMS Please wait appears saving is completed Then Device configuration screen appears again a...

Page 57: ... all BACnet Interoperability Building Blocks Supported Annex K SUPPORTED BIBBS BIBB NAME SUPPORTED REMARKS Data Sharing DS RP A Data Sharing ReadProperty A DS RP B Data Sharing ReadProperty B DS RPM A Data Sharing ReadPropertyMultiple A DS RPM B Data Sharing ReadPropertyMultiple B DS RPC A Data Sharing ReadPropertyConditional A DS RPC B Data Sharing ReadPropertyConditional B DS WP A Data Sharing W...

Page 58: ...wing and Modifying Trends External B T ATR A Automated Trend Retrieval A T ATR B Automated Trend Retrieval B T VMMV A Viewing and Modifying Multiple Values A T VMMV I B View and Modifying Multiple Values Internal B T VMMV E B View and Modifying Multiple Values External B T AMVR A Automated Multiple Value Retrieval A T AMVR B Automated Multiple Value Retrieval B Device and Network Management DM DDB...

Page 59: ...lly Creatable Dynamically Deletable Writeable Properties Analog Input Analog Output Analog Value Present value Binary Input Binary Output Present value Binary Value Present value Calendar Command Device Yes n a n a n a Event Enrollment File Group Loop Multi state Input Present value Multi state Output Multi state Value Present value Notification Class Recipient_List Program Schedule Segmentation C...

Page 60: ...figurations e g ARCNET Ethernet Ethernet MS TP etc Annex H BACnet Tunneling Router over IP BACnet IP Broadcast Management Device BBMD Does the BBMD support registrations by Foreign Devices Yes No Does the BBMD support network address translation Yes No Character Sets Supported Indicating support for multiple character sets does not imply that they can all be supported simultaneously ANSI X3 4 IBM ...

Page 61: ...stat usage Outing Binary Output DO Filter sign reset All Device off Binary Value Power On Off control Setting the fucntion of limiting lower temperature Setting the function of limiting upper temperatue SPI setting HumanSensor setting Humidification setting Outdoor air intake setting Ourdoor cooling setting Apply lower temperature limit for water out Apply upper temperature limit for water out App...

Page 62: ...it DNET Gateway number 9 Indoor Unit Address 01 01 32 Device ID 941732 9 417 32 Item DNET Range Digit 2 CPP Range Digit 3 INDOOR Range Digit 2 Centralized Controller 1 40 000 015 64 SIM 1 40 100 115 64 DMS DI DO 1 40 300 315 64 Interface Module 1 40 400 655 16 x 16 64 Indoor Unit ERV AHU kit EHS 1 40 400 655 0 63 Gateway 1 40 900 64 Object of device Detail Description of Object NASAS_MIM B17N_BACn...

Page 63: ...tatus BI AC_FilterSign_xx_xxxxxx False True 13 Filtersignreset BO AC_FilterSign_Reset_xx_xxxxxx False True 14 Operationmodestatus MV AC_Operation_Mode_xx_ xxxxxx Auto Cool Heat Fan Dry 15 Fanspeedstatus MV AC_FanSpeed_xx_xxxxxx Auto Low Mid High 16 Airflowdirectionstatus MV AC_FanFlow_xx_xxxxxx None Vertical Horizon All 17 Operationmodelimitstatus MV AC_Mode_Limit_xx_xxxxxx NoLimit CoolOnly HeatOn...

Page 64: ...terSign_Reset_xx_ xxxxxx False True 14 Operation mode status MV AHU_Operation_Mode_xx_ xxxxxx Auto Cool Heat Fan Dry 15 Operation mode limit status MV AHU_Mode_Limit_xx_ xxxxxx No Limit Cool Only Heat Only 16 Remote controller limit status MV AHU_Remocon_Limit_xx_ xxxxxx Enable RC Disable RC Conditional RC 17 Integrated error code of both indoor unit and outdoor unit AI AHU_Error_Code_xx_xxxxxx Re...

Page 65: ...xxxx C 16 Displayedtemperaturetype BI EHS_ControlTempType_xx_xxxxxx Room WaterOut 17 Thermostatusage BI EHS_Thermostat_xx_xxxxxx False True 18 Outing BI EHS_GoOut_xx_xxxxxx Off On 19 PowerOn Off BV EHS_Power_xx_xxxxxx Off On 20 Settinglowertemperaturelimit BV EHS_Cool_LimitTemp_Set_xx_xxxxxx False True Usewhendisplayedtempera turetypeissetto Room 21 Settinguppertemperaturelimit BV EHS_Heat_LimitTe...

Page 66: ... following point list Instance Number Object Object Type Object Name Status value 1 Centralized controller error code AI Central_Error_Code_xx_xx Refer to the list of the integrated error code 2 Centralized controller notify NC Central_Notify_xx_xx When the error occurred send event to list of destination in the recipient_list Max 8 Centralized controller Instance Number Object Object Type ObjectN...

Page 67: ...Type ObjectName Unit Statusvalue Inactive Active Text 1 Text 2 Text 3 Text 4 Text 5 1 Digital Input 1 BI DI_01_xx_xx BACnet Gateway Reserved Off On 2 Digital Input 2 BI DI_02_xx_xx BACnet Gateway Reserved Off On 3 Digital Input 3 BI DI_03_xx_xx Off On 4 Digital Input 4 BI DI_04_xx_xx Off On 5 Digital Input 5 BI DI_05_xx_xx Off On 6 Digital Input 6 BI DI_06_xx_xx Off On 7 Digital Input 7 BI DI_07_x...

Page 68: ...COMMUNICATION_FAILURE 2 Fault Alarm flag of Status_Flags property will be set as TRUE 3 Present_Value property is readable but the value is not guaranteed Main service Time setting Time synchronization Service is a service that allows the time of BACnet Gateway to be synchronized with the time of PC COV Change Of Value COV service is supported and you can set confirmed or unconfirmed COV You can s...