Water law
This function allows water outlet temperature to change
regarding demand load changes depending on outdoor
temperature and room temperature. It can be set to
increase energy efficiency and comfort.
f
Outdoor temperature standard
W
at
er ou
tle
t se
t t
emp
.
Outdoor temp. (Cool)
AirCool2
AirCool1
Tcool2
Tcool1
ŷ
If it is room temperature model,
water outlet set temperature
set by water law does not drop
below 5°C (41°F).
W
at
er ou
tle
t se
t t
emp
.
Outdoor temp. (Heat)
AirHeat2
AirHeat1
Theat2
Theat1
f
Room temperature standard
W
at
er ou
tle
t se
t t
emp
.
Room temp. (Cool)
RoomCool2
RoomCool1
Tcool2
Tcool1
ŷ
If it is room temperature model,
water outlet set temperature
set by water law does not drop
below 5°C (41°F).
W
at
er ou
tle
t se
t t
emp
.
Room temp. (Heat)
RoomHeat2
RoomHeat1
Theat2
Theat1
NOTE
ŷ
Refer to page 46 for set values of water outlet
set temperature (Tcool1, Tcool2, Theat1, Theat2),
outdoor temperature (AirCool1, AirCool2, AirHeat1,
AirHeat2), and room temperature (RoomCool1,
RoomCool2, RoomHeat1, RoomHeat2) in the hydro
controller option table No.15 ~ 27.