www.larius.com
18
THOR
ED.
17 - 09/2020 - Cod. 150096
Fig. 4J
Fig. 5J
Fig. 6J
MIN
MAX
J1
Circulation
and washing
Chiuso
J3
J5
J4
Make sure that the machine sucks in clean
washing liquid. Allow the cleaning liquid to
discharge into another container and do not mix
it with the cleaning liquid still to be used.
We recommend circulating the cleaning liquid for
at least 15 minutes.
For disposing of the washing liquid, see the
requirements laid down in the Standards in force
in the country in which the equipment is used and
act accordingly.
The Client is solely responsible for any irregular
action taken before, during, or after disposing of
washing liquid, or in interpreting and applying the
current Standards in this regard.
Use a metal container (J5).
To avoid any risk of electric shock connect the
collection container to a surface that is earthed
(e.g. concrete)
and not to surfaces that will insulate
the container from the earth.
Hold the spray gun against the edge of the metal
contained (J5).
•
Turn the pressure setting knob (
J1
) clockwise to the “CIR
-
CULATION & WASHING” position
(drop symbol)
.
• Close the circulation tap (
J3
).
•
Point the spray gun
(
J4
) into the container (
J5
) used to collect
the cleaning liquid
and hold the trigger down to expel any
product remaining, until clean liquid flows out
.
Now, release the trigger.
• Make sure that the product circulates through the circulation
hose.