www.larius.com
19
THOR
ED.
17 - 09/2020 - Cod. 150096
Fig. 7J
Fig. 8J
Fig. 9J
J6
J7
J4
J5
J2
OFF
Follow the washing procedure before using again
the equipment.
Make sure that the machine sucks in clean
washing liquid. Allow the cleaning liquid to
discharge into another container and do not mix
it with the cleaning liquid still to be used.
We recommend circulating the cleaning liquid for
at least 15 minutes.
• Lift the suction hose and remove the bucket of cleaning
liquid.
•
Now point the spray gun
(
J4
) into the container (
J5
)
and press
the trigger to recover any cleaning liquid left
.
• In case of long storage, we recommend you to suck and
to leave light mineral oil inside the pumping group and the
flexible hose
.
• Disassemble the “safety setting” valve (
J6
)
and the hose
(
J7
),
clean thoroughly, and reassemble everything in the reverse
order compared to disassembly
.
• Take the cleaning liquid and store it in suitable containers
.
•
As the pump idles, press the
“
OFF”
(0)
switch (J2) to stop