www.larius.com
17
THOR
ED.
17 - 09/2020 - Cod. 150096
Fig. 1J
Fig. 2J
Fig. 3J
J
J1
J2
OFF
ON
Open
J3
J2
CLEANING AT THE END OF
THE WORK
CLEANING FOR SOLVENT-BASED PRODUCTS
•
Reduce pressure to the minimum
(turn counterclockwise the
pressure control knob
(J1)
).
•
Press the switch (
H2
) placed on the box of the electric motor,
to stop the equipment.
•
Hold the spray gun trigger down.
• Open the circulation tap (
J3
) to discharge the pressure in the
circuit
.
• Lift the suction hose and replace the bucket containing the
product with a bucket of cleaning liquid
(make sure it is
compatible with the product you are using)
.
• Unscrew the nozzle on the spray gun
(remember to clean it
with cleaning liquid)
.
•
Press the switch (
J2
) “
ON”
(I)
of the equipment.
Make sure that the electrical system is earthed
and complies with regulations.