Diagnostic help / Troubleshooting guide
582195110-Complete_Pump-PRIMA-01D100-EN-indA
46
Defaults
Possible causes
Remedies
The pump does not work or
works slowly
Hose cross section too small
Change the hose using an hose with
a larger cross section.
Defective air distributor
Disassemble and inspect the air
distributor and pilot spool.
Exhaust pipe blocked or
collectors clogged
Check that the exhaust line valves
have not been inadvertently closed.
Clean the exhaust line or collectors.
Network pressure greater
than or equal to the air inlet
pressure
Increase the pump air pressure to a
maximum of 6 bar / 87 psi.
Air exhaust line muffler
clogged
Take off the muffler cover. Clean
or/and remove ice. Reinstall the
muffler.
Presence of pumped fluid in
the muffler of the air exhaust
line
Disassemble the pump chambers.
Check for damage to the fluid
and/or air diaphragms. Replace
them if necessary. Check the
tightness of the diaphragm washers
(tightening torque: 7.5 N.m. / 5.5
ft/Lbs).
Pumping chamber blocked
Disassemble and inspect wetted
chambers. Remove or empty any
items causing the blockage.
Valve leaks
Change the valve(s) and the
tightness seals.
Summary of Contents for PRIMA 01D100
Page 85: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 85 10 1 Exploded overview...
Page 87: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 87 10 3 Upper part and exhaust valves...
Page 88: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 88 10 4 Lower part and suction valves...
Page 89: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 89 10 5 Distributor...