Diagnostic help / Troubleshooting guide
582195110-Complete_Pump-PRIMA-01D100-EN-indA
45
8.1
Possible symptoms of faults / Causes of faults / Remedies to apply -
fast operation
WARNING
Before any intervention, it is imperative to follow the
Shut off the air inlet then depressurize the fluid network by opening
the gun.
Defaults
Possible causes
Remedies
The pump performs a single
cycle
Distributor or intermediate
tightness seals incorrectly
installed
Check the installation of the
distributor (notch).
Check for the presence of all base
seals. Replace them if necessary.
Check the presence of the plug
seals. Replace them if necessary.
Distributor piston missing or
deformed
Remove the distributor. Check the
piston condition. Replace it if
necessary.
The pump does not run or
carries out one cycle and
then stops
Ball stuck in the seat or worn
out due to overpressure or
use of abrasive or corrosive
products
Replace the ball and the seat.
Do not exceed the maximum fluid
pressure of 6 bar / 87 psi.
Check the chemical or technical
compatibility of the product.
The pump does not start
Incorrect air supply
Check the pump air supply. Check
the size and length of the air line.
The pump does not work or
the pressure varies
Polluted product. Pump not
properly installed or badly
used
Check the power supply. Follow the
installation and operating
instructions in the instruction manual.
Summary of Contents for PRIMA 01D100
Page 85: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 85 10 1 Exploded overview...
Page 87: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 87 10 3 Upper part and exhaust valves...
Page 88: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 88 10 4 Lower part and suction valves...
Page 89: ...Spare parts 582195110 Complete_Pump PRIMA 01D100 EN indA 89 10 5 Distributor...