Start up
582195110-Complete_Pump-PRIMA-01D100-EN-indA
41
7
Start up
WARNING
7.1
Commissioning instructions
During operation, make sure that the pump is always completely
filled with liquid.
Make sure that the outlet point of the fluid to be conveyed is not
clogged or closed.
The pump fluid can react with the material of the pump. Before
pumping the fluid, check the suitability of the pump materials for
the fluid to be pumped.
Operation of the pump above the permissible flow rate and
longer dry operation can cause overheating of the pump.
Risk of dangerous heating of the fluid during the exhaust phase.
The special operating conditions of the pump must be kept in
mind and adhered to.
First commissioning of the pump must be conducted through a
person qualified for that purpose.
If the pump is not mounted on a horizontal, even surface with
the pump feet at the bottom, vent the pump chambers.
Adjust the air pressure between 1 / 14.5 psi to 6 bar / 87 psi. The
pump is ready for operation.
Operate the pump with a maximum air pressure of 6 bar / 87 psi.
WARNING
Risk of pump destruction and bursting due to excessive air pressure.
Risk of diaphragms destruction due to excessive air pressure.