Basic Operation Instruction
91
-
144
CV50 inverters support the shifting between different reference channels and the detailed shifting rules are as
below:
Current
reference
channel
P00.09
Multi-function terminal =
13
Shifting from A channel
to B channel
Multi-function terminal =
14. Shifting from
combination setting to A
channel
Multi-function terminal =
15. Shifting from
combination setting to B
channel
A B
/
/
B A
/
/
A+B /
A
B
A-B /
A
B
Max (A,B)
/
A
B
Min (A,B)
/
A
B
Note:
“
/
”
means the multi-function terminal is invalid under the current reference channel.
When select multi-function terminal UP (10) and DOWN (11) to set the internal assistant frequency, P08.45
and P08.46 can be set to increase or decrease the set frequency quickly.