40 - 144
Function Parameters
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
Setting range of P01.09: 0.00Hz~P00.03 (the Max. frequency)
Setting range of P01.10: 0.00~50.00 s
Setting range of P01.11: 0.0~100.0 %
Setting range of P01.12: 0.00~50.00 s
P01.13
Dead time of
FWD/REV
rotation
During the procedure of switching FWD/REV rotation, set
the threshold by P01.14, which is as the table below:
Setting range: 0.0~3600.0 s
0.0 s
○
P01.14
Shifting
between
FWD/REV
rotation
Set the threshold point of the inverter:
0: Switch after 0 frequency
1: Switch after the starting frequency
2: Switch after the speed reach P01.15 and delay for P01.24
0
◎
P01.15 Stopping speed 0.00~100.00Hz
0.50 Hz
◎
P01.16
Detection
of stopping
speed
0: Detect according to speed setting
(no stopping delay)
1: Detect according to speed feedback
(only valid for
vector control)
1
◎
P01.17
Detection time
of the feedback
speed
If set P01.16 to 1, the feedback frequency is less than or equal
to P01.15 and detect in the set time of P01.17, the inverter will
stop; otherwise the inverter will stop after the set time of P01.17
Setting range: 0.00~100.00 s (only valid when P01.16=1)
0.50 s
◎