Basic Operation Instruction
85
-
144
7 Basic Operation Instruction
7.1 What this chapter contains
This chapter describes the internal function mode of the inverter in details.
Check all terminals are connected properly and tightly.
Check that the power of the motor corresponds to that of the inverter.
7.2 First powering on
Check before powering on
Please check according to the installation list in chapter two.
Original powering operation
Check to ensure there is no mistake in wiring and power supply. Switch on the circuit breaker of the AC power
supply on the input side of the inverter to power on the inverter. 8.8.8.8.8. will be displayed on the keypad.
Check also if the contactor closes normally. When the characters on the display change to the set frequency,
the inverter has finished the initialization and it is in the stand-by state.
Below diagram shows the first operation: (take motor 1 as the example)