![background image](http://html.mh-extra.com/html/sage/930i/930i_operating-manual_799956110.webp)
5-63
© Sage Instruments 2000
9100-2930-02 01/31/00
Sage Instruments 930i Communications Test Set
The display reads:
SET TLP 0dB USER -2dB
K1
K2
K3
K4
2. Press K1 to advance to the next display without changing any parameters, or press K2 to select
0 dB
, or press K3 under
USER
( in analog mode) if you need to set a Send or Receive TLP value
other than the standard
0 dB
or
-2 dB
values, or press K4 to select
-2 dB TLP
.
If you select a
0 dB
or
-2 dB TLP,
you will be advanced to step 5.
If you press K3 to select a nonstandard TLP, the display reads:
SEND: +0dBm RECV: +0dBm EXIT
K1
K2
K3
K4
3. Press K1 to change the
SEND TLP
OR
K3 to change the
RECV TLP
.
4. Use the numeric keypad to enter the desired TLP.
• A valid
SEND TLP
is between
-16 dBm
and
+3 dBm
.
• A valid
RECV TLP
is between
-16 dBm
and
+3 dBm
.
5. Press K4 under
EXIT
. You will then advance to the initial Dial/Ring display to set up and make
your call. This display will differ depending on whether you are in analog or PCM mode. Refer
to
Section 3-2.2.1
for a description of the Dial/Ring function in analog, and
Section 3-2.2.2
for a description of Dial/Ring in PCM.
Note:
Before the 930i can operate as a far end responder in PCM, you must select and set up a protocol
(if one has not already been selected under the Dial/Ring function key), and set up your dial
digits. Refer to
Section 3-2.2
for a complete description of this procedure.
When accessed by ringing or far-end seizure, the 930i goes off-hook and responds with a 2225 Hz test
progress tone (TPT). The 930i then waits for MF commands and performs the corresponding Type 105
tests. The 930i will continue in this mode until one of the following occurs:
• It is released by the calling party via an MF “release” command.
• The calling party goes on-hook (see following notes).
• No MF command is received for 20 seconds (930A defaults to Manual mode if selected).
• The operator selects OFF or discontinues testing in any way.
Option Menu #:
25
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for 930i
Page 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 19: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 43: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 203: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 235: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...