Sage Instruments 930i Communications Test Set
Front Panel
Operation
A protocol is an algorithm or set of cooperating algorithms capable of making, receiving, or monitoring
the setup of a telephone call on a particular type of telephone trunk connected to the 930i. The 930i has
been shipped with a limited number of pre-installed protocols which can be selected and set up under
the Dial/Ring function key. (Refer to
Section 3-2.1.
)
In addition to these pre-installed protocols, custom-designed protocols can be added for almost any
conceivable combination or permutation of protocol requirements. This flexability is indispensable in a
global market where telephone systems and protocols differ from country to country or even from region
to region within a country.
From the 930i user’s standpoint, the unit is easy to use, where calls are made or monitored through the
Dial/Ring function key and protocols are selected and set up from there using the setup menu.
Before making or receiving a call:
1. Press the K3 under
SETUP
from the main display. The new display reads:
SELECT: PROTOCOL PARAMS SPAN START
K1
K2
K3
K4
2. Press K1 under
PROTOCOL
. The display will look similar to the following:
SELECT: POTS R2Simpl R2ITU MORE
K1
K2
K3
K4
The 930i is shipped with several pre-installed protocols:
POTS
POTS Allows you to make a standard call on a POTS trunk. MF, DTMF and DP digits can be selected.
Parameter
Default
Description
N DIGITS
0
The 930i will automatically answer after N Digits have
been received. If N=0, the user must go off hook to manu-
ally answer or wait for the Digit Timout.
DIGIT TIMOUT
5000 ms
If N Digits have not been received, the unit will answer
after this amount of time has elapsed.
HANGUP DELAY
1000 ms
When the unit at the user end hangs up, the near end will
wait for this amount of time before going on hook.
ABORT TIME
100 ms
After a call has fbeen aborted by going on hook, the unit
will wait this amount of time before sending an on hook
signal.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for 930i
Page 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 19: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 43: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 203: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Page 235: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...