5-7
© Sage Instruments 2000
9100-2930-02 01/31/00
Sage Instruments 930i Communications Test Set
Option Menu #:
1
5-1.3.2 Frequency
To change the output frequency:
1. Press K2 under
FREQ
. The display reads:
20 Hz DEFAULT EXIT
K1
K2
K3
K4
2. Use the numeric keypad to enter a new frequency.
• A valid frequency is between
15 Hz
and
65 Hz
with a default of
20 Hz
.
3. Press K4 to exit to the
MODIFY
display.
5-1.3.3 Timing
To change the timing interval:
1. Press K3 under
TIMING
. The display reads:
2000 ON 4000 OFF DEFAULT EXIT
K1
K2
K3
K4
2. Press K1 to change the ON time or K2 to change the OFF time.
3. Use the numeric keypad to enter a new interval.
• A valid timing interval is between
150 ms
and
9999 ms
, with a default of
2000 ms
for
ON and
4000 ms
for OFF.
4. Press K4 to exit to the
MODIFY
display.