background image

11

 

/

 34 • GAFM-II-10.12 

 

airflow to be investigated, 

in any position of the device.

  

When the tank is full and the battery completely charged, 

fog can be generated contin-

uously for about 21 minutes.

 Usually, the fog flow is only needed for some seconds, i.e. 

the device will be used only impulsively. 

 

 

The 

FlowMarker

®

 

model II

 is equipped with a shut-off feature, it enables the user to turn 

the device completely off at any time. For this the blue button must be pressed 4 s 
permanently. First the white LED will light up briefly, then it turns off and the red LED 
displays the switching off by extinguishing itself too after a second. The unit is now 
internal completely powerless, 

only the power input socket is still connected to the 

battery

.  

If there are 

additional devices connected to the charging socket

 of the

 

FlowMarker

®

  

(e. g. the 

FM-HYDRA-TUBE SYSTEM

©

), they must therefore always be 

switched off 

separately,

 they 

cannot

 switch 

off automatically

!

 

 

Now, it is ensured that the built-in battery will not be harmfully deep discharged. However 
the battery should be charged completely before the device is not in use for very long 
time, because this significantly increases the service life of the lead/gel battery.  

 

 

For a as long as possible battery life the 

FlowMarker

®

 

model II

 is now equipped with an 

energy saving mode.

  

If after activating of the device heating no fog has been produced within 2 
minutes, in other words the blue button has not be pushed, the device is switching 
into the energy saving mode. 

 

This mode is decreasing the heat exchanger temperature slightly, but allows the user

 any 

time to press the fog button again.

 The fog production starts than only with some 

seconds of delay (maximum 6 seconds, depending on the length of the interruption of 
use). 

Is no fog is generated in this mode 

within 15 minutes,

 the device automatically switches 

into the so-called 

SLEEP MODE

 in which the heating functions come to a standstill. Only 

if necessary inserted wireless or cable remote controls are supported yet. 

Using a remote control or pressing the fog button on the device the 

SAFEX

®

-

FlowMarker

®

 however can always be briefly activated (heated up) again.

 

 

This sleeping mode is maintained also for 

2 hours.

 Should this period pass 

without

 

producing fog, the built-in microprocessor 

switches off completely the device

 (all LEDs 

go out), to ensure that the battery of a “forgotten”

 

FlowMarker

®

 will not soon or later 

destructively deep discharged! 

 

 

The 

SAFEX

®

-FlowMarker

®

 can excellently be used also stationary, where the fog 

generation in these cases is then beneficial started with a remote control. 

For this the device is equipped with a remote control socket, to which an optional availa-
ble 

SAFEX

®

- RADIO-

 

or 

CABLE

 

REMOTE CONTROL

 can be connected (see chapter  „G“ 

OPTIONAL ACCESSORIES).  

By each short pressing of the pushbutton of the remote control the fog flow will be turned 
on or off again. However, it may, depending on the ready state of the device possibly take 
some seconds until the fog is released. 

The switching status is recognizable again at the 

SAFEX

®

-FlowMarker

®

 by the white 

LED. (white LED lights up = fog function is activated ). 

ENERGY SAVING

MODE

 

TURNING OFF

UNIT 

OPERATION WITH RE-

MOTE CONTROLS

Summary of Contents for FlowMarker II

Page 1: ...FlowMarker II Instruction Manual Gebrauchsanleitung 1 03...

Page 2: ......

Page 3: ...itshinweise sollten vor Gebrauch unbedingt gelesen werden DISTRIBUTOR VERTRIEB Tintschl BioEnergie und Str mungstechnik AG Goerdeler Stra e 21 D 91058 Erlangen Tel 49 0 91 31 81 24 97 30 Fax 49 0 91 3...

Page 4: ...ruction manual the MSDS for the Fog Fluid and other data sheets are available as PDF downloads at several homepages the most actual versions are available at www tintschl best de Deutsche Gebrauchsanw...

Page 5: ...ENTS S 5 6 Instruction Manual A System description 7 B Preparing device for operation 8 C Using FlowMarker 10 D Maintenance and care 13 E Storage and transportation 15 F Safety instructions 16 G Optio...

Page 6: ...hub Batterie Figure 2 Abb 2 Use with application tube AR1 20 New Verwendung mit Applikatorrohr AR 1 Neu Thread for application tube Gewindeaufnahme f r Applikator Nozzle D se AR1 20 New with red or bl...

Page 7: ...battery Batterie laden Battery charger Batterie Ladeger t Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Fill opening Bef ll ffnung Fill stem F llstift Pressurized...

Page 8: ...is been done It further will be switched into the so called SLEEP MODE when continuously not be used and finally after a longer non use the unit turns itself off completely The battery capacity is sp...

Page 9: ...ly half full of fog fluid for a quick starting test a Place the fog fluid aerosol can upright on a solid base Remove the valve protection cap Hold the can with one hand A filling is possible only with...

Page 10: ...ights up permanently See for this section D MAINTENACE AND CARE Charging the battery In this way the user can recognize early on that a recharging of the battery is impending one can therefore usually...

Page 11: ...plication tube can be reduced or completely closed This has a considerable influence on the fog and its flow The fog can therefore be generated according to the user s requirements To collect the fog...

Page 12: ...de This mode is decreasing the heat exchanger temperature slightly but allows the user any time to press the fog button again The fog production starts than only with some seconds of delay maximum 6 s...

Page 13: ...id must be refilled if necessary For this however disconnect tempo rarily the power supply For special applications extension tubes are available or can be developed Presently the following variations...

Page 14: ...comes to an end and in regards to its working program taking this in consideration The battery is charged regularly inside the device The included international mains charging adapter generates the ne...

Page 15: ...absorbent paper Before the next filling clean the opening of dust and fluff with a soft brush or warm water All case components are made of stainless steel But do not let any water get into the devic...

Page 16: ...s are available as an accessory The smaller ring KR3 has to be inserted from the muzzle side of the black tube The larger ring KR2 has to be inserted from the threaded side of the application tube unt...

Page 17: ...apter is used which fulfils local safety requirements Please notice 1 The machines are equipped with a safety device If the heating does not work properly the machine will turn in a safe condition 2 R...

Page 18: ...to be inserted from the threaded side of the application tube until it fits behind the air inlet holes at the recess It must not cover the air holes The smaller ring KR3 has to be inserted from the m...

Page 19: ...r REMOTE CONTROLS can be connected FlowMarker CABLE REMOTE CONTROL 10 m simple but robust cable remote control with highly flexible thin cables With a push of a button the fog can be triggered from di...

Page 20: ...ing fog button lasting 2 hours SELF SHUTOFF OF DEVICE circa 2 hours 17 minutes after last pressing fog button HEAT UP TIME max 30 seconds for cold device max 6 sec in energy saving mode FOGGING AGENT...

Page 21: ...lemente S 5 6 GEBRAUCHSANWEISUNG A Systembeschreibung S 21 B Ger tevorbereitung S 22 C Inbetriebnahme S 24 D Wartung und Pflege S 27 E Lagerung und Transport S 30 F Sicherheitshinweise S 30 G Optional...

Page 22: ...nden Spar sowie danach in einen sog Schlafmodus und bei l ngerem Nichtgebrauch sogar selbstst ndig aus Auf diese Weise wird die Batteriekapazit t geschont das Ger t bleibt l nger betriebsf hig und auc...

Page 23: ...bef llt und entl ftet um eine erste Erprobung zu erm glichen a Dazu Nebelfluid Dose senkrecht auf eine Unterlage stellen Ventilschutzkappe abnehmen und Dose mit einer Hand festhalten Eine Bef llung is...

Page 24: ...l LED blinkt zun chst und leuchtet sp ter permanent auf Siehe dazu Abschnitt D Wartung und Pflege Auf diese Weise erkennt der Anwender recht fr h dass ein Nachladen der Batterie bevor steht er kann so...

Page 25: ...warzen Kunststoffringes versehen Durch seitliches Verdrehen des Ringes k nnen die sechs Luftzuf hr ffnungen im Applikator verkleinert oder ganz verschlossen werden was deutliche Auswirkung auf den Neb...

Page 26: ...r eine m glichst lange Batterienutzungsdauer ist das SAFEX FlowMarker Modell II jetzt mit einem ENERGIE SPARMODUS ausger stet Wird nach Aktivierung der Ger teheizung innerhalb von ca 2 Minuten kein Ne...

Page 27: ...orgenommen kann aber auch an vorhandenen Ger ten nachger stet werden z B auch von Service Stationen Insbesondere f r station re aber auch f r mobile Anwendungen kann es sinnvoll sein den SAFEX FlowMar...

Page 28: ...TUNG UND PFLEGE D Gelegentlich kann sich nach l ngerem Nichtgebrauch der Tankkolben des FlowMar ker festsetzen Dies ist jedoch kein wirklicher Defekt sondern kann einfach behoben werden indem man mit...

Page 29: ...wechsel der LED am Ladeger t angezeigt Im Ger tetank befindliche Nebelfluide k nnen ohne Beeintr chtigung bis zu 2 Jahren im Ger t verbleiben Auch die SAFEX NEBELFLUID Druckgaspackung ist mindestens 2...

Page 30: ...Dose steht jedoch unter Gasdruck und ist daher als Gefahrgut im Sinne internationaler Transportvorschriften als UN Nr 1950 DRUCKGASPACKUNG erstickend Klasse 2 Kat 5A anzusehen Das Druckgas ist unbrenn...

Page 31: ...rden bevor es zur ck auf das Ger t montiert wird E LAGERUNG UND TRANSPORT Wird das Ger t l nger als 3 Monate nicht ben tigt und soll es nicht w hrend der Lagerung mit dem Netzteil verbunden bleiben so...

Page 32: ...in k nnen In Zweifelsf llen Bat terie aus dem Ger t entnehmen und dieses zur Reparatur einsenden 4 Unsachgem e Reparaturen bzw Ver nderungen der Regeleinrichtungen k nnen zu Gefahren und zur Zerst run...

Page 33: ...eingeschoben Die Ringe nehmen eventuell austretendes Kondensat auf m ssen jedoch bei intensiverem Gebrauch des Ger tes regelm ig erneuert werden Die SAFEX NEBELFLUID Druckgaspackung steht unter Druck...

Page 34: ...Die folgenden FlowMarker FERNSTEUERUNGEN k nnen so angeschlossen werden FlowMarker Kabelfernsteuerung 10 m einfache jedoch robuste Kabelfernsteuerung mit hochflexiblen d nnem Kabel mit dem durch Knop...

Page 35: ...ebeltasters 2 h andauernd GER TE SELBSTABSCHALTUNG circa 2 h und 17 min nach letzter Bet tigung des Nebeltasters AUFHEIZZEIT max 30 Sek bei kaltem Ger t BETRIEBSSTOFF ausschlie lich SAFEX FlowMarker N...

Page 36: ......

Reviews: