USING FLOWMARKER  II 

 

The device should be equipped with a 

charged battery, the application tube

 

and filled with an appropriate amount of fog fluid. 

 

Start device by short pressing of the 

blue button,

 the 3 LED’s flash up briefly. 

The device starts the heating operation (recognizable by the increased flashing 
of the Green LED), until it reaches the 

operating temperature

 after approxi-

mately 20 to 30 seconds. This is recognizable by a 

permanent lighting up of 

the green LED.

  

 

The device is now ready for use. Fog can be created now within the next 2 
minutes without delay. If the 2 minutes elapse without any fog produced, the 
unit switches for 15 minutes in the 

energy saving mode,

 which spares the 

battery capacity. In this mode however 

fog can be produced at any time

 with 

a short delay of maximum 6 s! 

 

 

To use the special advantages of the patented 

SAFEX

®

-FlowMarker

®

 the 

FOG APPLICA-

TION TUBE

 is necessary for low-impulse and thermal neutral fog generation.  

By default, the device is equipped with the 30 cm long version

 AR1

 with the silver basic 

threaded part and a black plastic pipe (20 mm oØ). Due to its special design and material, 
the escaping fog is brought to the surrounding room temperature and is flow technologi-
cal “calmed down”. 

In addition, a black plastic ring on the application tube base serves as 

controllable air 

inlet.

 By turning the ring, the six air inlets in the application tube can be reduced or 

completely closed. This has a considerable influence on the fog and its flow. 

The fog can therefore be generated according to the user’s requirements. 

To collect the fog fluid that unavoidably condenses in the tube, the enclosed con-
densation absorbing rings should be inserted according to section „D“ MAINTE-
NANCE AND CARE  on page 13. 

 

 

Manual use: 

 

If one would like to manually work with the device, briefly press the blue fog 
button, then the device produces the fog (if necessary the heating process starts 
first shortly, see previously). 

This switching operation (active mist generation) is recognizable by the 

white 

LED

 

“FOG”

, it will light up permanently as long as the fog production is activated. 

This also applies to the operation of the device by means of a remote con-
trol. 

This display of the activated fog generation is useful when for example the fog 
flow is not immediately visible due to air in the fluid channels or by using an addi-
tional fog ducting hose or long application tube etc. 

 

To 

stop the fog production,

 the blue button is briefly to be pressed again 

(switch-off process, white LED “FOG” goes off).

 

 

Should the work with the device be immediately terminated, the 

complete 

power off is achieved by a 4 s long, ongoing pressure on the blue button.

 

All LEDs flash up briefly, 

after the red LED has gone out

 the device is 

com-

pletely turned off.

 

The

 

SAFEX

®

-FlowMarker

®

 has been constructed for use in any position of operation. By 

means of the application tube, the fog can be applied at the desired place or into the 

GENERATING FOG

 

ACTIVATING DEVICE

APPLICATION TUBE

 

Summary of Contents for FlowMarker II

Page 1: ...FlowMarker II Instruction Manual Gebrauchsanleitung 1 03...

Page 2: ......

Page 3: ...itshinweise sollten vor Gebrauch unbedingt gelesen werden DISTRIBUTOR VERTRIEB Tintschl BioEnergie und Str mungstechnik AG Goerdeler Stra e 21 D 91058 Erlangen Tel 49 0 91 31 81 24 97 30 Fax 49 0 91 3...

Page 4: ...ruction manual the MSDS for the Fog Fluid and other data sheets are available as PDF downloads at several homepages the most actual versions are available at www tintschl best de Deutsche Gebrauchsanw...

Page 5: ...ENTS S 5 6 Instruction Manual A System description 7 B Preparing device for operation 8 C Using FlowMarker 10 D Maintenance and care 13 E Storage and transportation 15 F Safety instructions 16 G Optio...

Page 6: ...hub Batterie Figure 2 Abb 2 Use with application tube AR1 20 New Verwendung mit Applikatorrohr AR 1 Neu Thread for application tube Gewindeaufnahme f r Applikator Nozzle D se AR1 20 New with red or bl...

Page 7: ...battery Batterie laden Battery charger Batterie Ladeger t Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Fill opening Bef ll ffnung Fill stem F llstift Pressurized...

Page 8: ...is been done It further will be switched into the so called SLEEP MODE when continuously not be used and finally after a longer non use the unit turns itself off completely The battery capacity is sp...

Page 9: ...ly half full of fog fluid for a quick starting test a Place the fog fluid aerosol can upright on a solid base Remove the valve protection cap Hold the can with one hand A filling is possible only with...

Page 10: ...ights up permanently See for this section D MAINTENACE AND CARE Charging the battery In this way the user can recognize early on that a recharging of the battery is impending one can therefore usually...

Page 11: ...plication tube can be reduced or completely closed This has a considerable influence on the fog and its flow The fog can therefore be generated according to the user s requirements To collect the fog...

Page 12: ...de This mode is decreasing the heat exchanger temperature slightly but allows the user any time to press the fog button again The fog production starts than only with some seconds of delay maximum 6 s...

Page 13: ...id must be refilled if necessary For this however disconnect tempo rarily the power supply For special applications extension tubes are available or can be developed Presently the following variations...

Page 14: ...comes to an end and in regards to its working program taking this in consideration The battery is charged regularly inside the device The included international mains charging adapter generates the ne...

Page 15: ...absorbent paper Before the next filling clean the opening of dust and fluff with a soft brush or warm water All case components are made of stainless steel But do not let any water get into the devic...

Page 16: ...s are available as an accessory The smaller ring KR3 has to be inserted from the muzzle side of the black tube The larger ring KR2 has to be inserted from the threaded side of the application tube unt...

Page 17: ...apter is used which fulfils local safety requirements Please notice 1 The machines are equipped with a safety device If the heating does not work properly the machine will turn in a safe condition 2 R...

Page 18: ...to be inserted from the threaded side of the application tube until it fits behind the air inlet holes at the recess It must not cover the air holes The smaller ring KR3 has to be inserted from the m...

Page 19: ...r REMOTE CONTROLS can be connected FlowMarker CABLE REMOTE CONTROL 10 m simple but robust cable remote control with highly flexible thin cables With a push of a button the fog can be triggered from di...

Page 20: ...ing fog button lasting 2 hours SELF SHUTOFF OF DEVICE circa 2 hours 17 minutes after last pressing fog button HEAT UP TIME max 30 seconds for cold device max 6 sec in energy saving mode FOGGING AGENT...

Page 21: ...lemente S 5 6 GEBRAUCHSANWEISUNG A Systembeschreibung S 21 B Ger tevorbereitung S 22 C Inbetriebnahme S 24 D Wartung und Pflege S 27 E Lagerung und Transport S 30 F Sicherheitshinweise S 30 G Optional...

Page 22: ...nden Spar sowie danach in einen sog Schlafmodus und bei l ngerem Nichtgebrauch sogar selbstst ndig aus Auf diese Weise wird die Batteriekapazit t geschont das Ger t bleibt l nger betriebsf hig und auc...

Page 23: ...bef llt und entl ftet um eine erste Erprobung zu erm glichen a Dazu Nebelfluid Dose senkrecht auf eine Unterlage stellen Ventilschutzkappe abnehmen und Dose mit einer Hand festhalten Eine Bef llung is...

Page 24: ...l LED blinkt zun chst und leuchtet sp ter permanent auf Siehe dazu Abschnitt D Wartung und Pflege Auf diese Weise erkennt der Anwender recht fr h dass ein Nachladen der Batterie bevor steht er kann so...

Page 25: ...warzen Kunststoffringes versehen Durch seitliches Verdrehen des Ringes k nnen die sechs Luftzuf hr ffnungen im Applikator verkleinert oder ganz verschlossen werden was deutliche Auswirkung auf den Neb...

Page 26: ...r eine m glichst lange Batterienutzungsdauer ist das SAFEX FlowMarker Modell II jetzt mit einem ENERGIE SPARMODUS ausger stet Wird nach Aktivierung der Ger teheizung innerhalb von ca 2 Minuten kein Ne...

Page 27: ...orgenommen kann aber auch an vorhandenen Ger ten nachger stet werden z B auch von Service Stationen Insbesondere f r station re aber auch f r mobile Anwendungen kann es sinnvoll sein den SAFEX FlowMar...

Page 28: ...TUNG UND PFLEGE D Gelegentlich kann sich nach l ngerem Nichtgebrauch der Tankkolben des FlowMar ker festsetzen Dies ist jedoch kein wirklicher Defekt sondern kann einfach behoben werden indem man mit...

Page 29: ...wechsel der LED am Ladeger t angezeigt Im Ger tetank befindliche Nebelfluide k nnen ohne Beeintr chtigung bis zu 2 Jahren im Ger t verbleiben Auch die SAFEX NEBELFLUID Druckgaspackung ist mindestens 2...

Page 30: ...Dose steht jedoch unter Gasdruck und ist daher als Gefahrgut im Sinne internationaler Transportvorschriften als UN Nr 1950 DRUCKGASPACKUNG erstickend Klasse 2 Kat 5A anzusehen Das Druckgas ist unbrenn...

Page 31: ...rden bevor es zur ck auf das Ger t montiert wird E LAGERUNG UND TRANSPORT Wird das Ger t l nger als 3 Monate nicht ben tigt und soll es nicht w hrend der Lagerung mit dem Netzteil verbunden bleiben so...

Page 32: ...in k nnen In Zweifelsf llen Bat terie aus dem Ger t entnehmen und dieses zur Reparatur einsenden 4 Unsachgem e Reparaturen bzw Ver nderungen der Regeleinrichtungen k nnen zu Gefahren und zur Zerst run...

Page 33: ...eingeschoben Die Ringe nehmen eventuell austretendes Kondensat auf m ssen jedoch bei intensiverem Gebrauch des Ger tes regelm ig erneuert werden Die SAFEX NEBELFLUID Druckgaspackung steht unter Druck...

Page 34: ...Die folgenden FlowMarker FERNSTEUERUNGEN k nnen so angeschlossen werden FlowMarker Kabelfernsteuerung 10 m einfache jedoch robuste Kabelfernsteuerung mit hochflexiblen d nnem Kabel mit dem durch Knop...

Page 35: ...ebeltasters 2 h andauernd GER TE SELBSTABSCHALTUNG circa 2 h und 17 min nach letzter Bet tigung des Nebeltasters AUFHEIZZEIT max 30 Sek bei kaltem Ger t BETRIEBSSTOFF ausschlie lich SAFEX FlowMarker N...

Page 36: ......

Reviews: