The fog fluid itself 

is harmless and no hazardous material.

 The can, however, is under 

gas pressure and therefore classified as hazardous material according to international 
transport regulations as 

UN No. 1950 AEROSOL asphyxiatin, class 2 – Cat. 5A

The pressure gas is non-flammable, non-toxic and ecologically harmless.

 

 

The pressure of the can is 

independent

 of the temperature. It gets less with every filling. 

Hence, every filling of the tank takes several seconds longer.  

In order not to “deaerate” the can incorrectly, 

always fill the device with the fill stem 

of the can pointing up.

 Filling in a horizontal or other position of the can is actual not 

possible. 

For particular applications it may be necessary to generate only very small amounts of 
fog. As the amount of fog discharge depends on the amount of the tank filling, it may be 
advantageous to fill the tank only at one third or halfway. 

 

 

It is unavoidable that some condensation will occur in the fog application tube during 
intensive use of the FlowMarker. 

In well ventilated warm areas a possible fluid condensation, for example on a could sur-
face, will dry up 

without leaving a residue.

 In the application tube however it is likely 

that under intensive use the condensed fluid film will increase and fluid may drop out of 
the tube.  

To avoid a slide risk 

condensation absorbing rings are available as an accessory.

 

The smaller ring 

KR3 has to be inserted from the muzzle side

 of the black tube.

 

The larger ring 

KR2 has to be inserted from the „threaded“ side

 of the application 

tube until it fits in 

behind the air inlet holes

 at the recess. 

The rings will absorb possible fluid condensation and may dry out if the 

FlowMarker

®

 

is 

not used. However they have to be replaced periodically depending on the intensity of 
use, at the latest when they are completely soaked. 

To 

remove the “front” ring KR3, use the attached plastic tube

 and push it out from 

the rear end. 

To remove the KR2 ring, flush the tube inside with warm water and let the ring get 
soft before pulling it out. 

 

If necessary put the applicator tube end in warm water for some 15 min., remove the ring, 
clean it from fluid residues and other impurities and wipe the tube completely dry before 
mounting it back to the FlowMarker.     

 

 

 

STORAGE AND TRANSPORTATION          E  

If the FlowMarker will not be needed for more than 3 months and will not be connected to 
the power supply during this time, 

charge the battery completely and take it out of 

the device.

 IMPORTANT: Also 

do not store

 the device with 

brimful tank

 over long time

Such preparation makes the battery 

storable for up to 2 years

 without suffering any 

damage.  

During storage and transportation strictly prevent the battery contacts from being short-
circuited by conductive materials such as metal, carbon fiber, graphite, foils etc. Other-
wise there 

is a serious fire risk.  

CONDENSATE-

ABSORBING

RINGS

FOG FLUID CAN AND FLU-

ID PRESSURE

 

KR3 

KR2 

Summary of Contents for FlowMarker II

Page 1: ...FlowMarker II Instruction Manual Gebrauchsanleitung 1 03...

Page 2: ......

Page 3: ...itshinweise sollten vor Gebrauch unbedingt gelesen werden DISTRIBUTOR VERTRIEB Tintschl BioEnergie und Str mungstechnik AG Goerdeler Stra e 21 D 91058 Erlangen Tel 49 0 91 31 81 24 97 30 Fax 49 0 91 3...

Page 4: ...ruction manual the MSDS for the Fog Fluid and other data sheets are available as PDF downloads at several homepages the most actual versions are available at www tintschl best de Deutsche Gebrauchsanw...

Page 5: ...ENTS S 5 6 Instruction Manual A System description 7 B Preparing device for operation 8 C Using FlowMarker 10 D Maintenance and care 13 E Storage and transportation 15 F Safety instructions 16 G Optio...

Page 6: ...hub Batterie Figure 2 Abb 2 Use with application tube AR1 20 New Verwendung mit Applikatorrohr AR 1 Neu Thread for application tube Gewindeaufnahme f r Applikator Nozzle D se AR1 20 New with red or bl...

Page 7: ...battery Batterie laden Battery charger Batterie Ladeger t Figure 4 Abb 4 Filling FLOW MARKER with FOG FLUID FLOWMARKER mit FOGFLUID bef llen Fill opening Bef ll ffnung Fill stem F llstift Pressurized...

Page 8: ...is been done It further will be switched into the so called SLEEP MODE when continuously not be used and finally after a longer non use the unit turns itself off completely The battery capacity is sp...

Page 9: ...ly half full of fog fluid for a quick starting test a Place the fog fluid aerosol can upright on a solid base Remove the valve protection cap Hold the can with one hand A filling is possible only with...

Page 10: ...ights up permanently See for this section D MAINTENACE AND CARE Charging the battery In this way the user can recognize early on that a recharging of the battery is impending one can therefore usually...

Page 11: ...plication tube can be reduced or completely closed This has a considerable influence on the fog and its flow The fog can therefore be generated according to the user s requirements To collect the fog...

Page 12: ...de This mode is decreasing the heat exchanger temperature slightly but allows the user any time to press the fog button again The fog production starts than only with some seconds of delay maximum 6 s...

Page 13: ...id must be refilled if necessary For this however disconnect tempo rarily the power supply For special applications extension tubes are available or can be developed Presently the following variations...

Page 14: ...comes to an end and in regards to its working program taking this in consideration The battery is charged regularly inside the device The included international mains charging adapter generates the ne...

Page 15: ...absorbent paper Before the next filling clean the opening of dust and fluff with a soft brush or warm water All case components are made of stainless steel But do not let any water get into the devic...

Page 16: ...s are available as an accessory The smaller ring KR3 has to be inserted from the muzzle side of the black tube The larger ring KR2 has to be inserted from the threaded side of the application tube unt...

Page 17: ...apter is used which fulfils local safety requirements Please notice 1 The machines are equipped with a safety device If the heating does not work properly the machine will turn in a safe condition 2 R...

Page 18: ...to be inserted from the threaded side of the application tube until it fits behind the air inlet holes at the recess It must not cover the air holes The smaller ring KR3 has to be inserted from the m...

Page 19: ...r REMOTE CONTROLS can be connected FlowMarker CABLE REMOTE CONTROL 10 m simple but robust cable remote control with highly flexible thin cables With a push of a button the fog can be triggered from di...

Page 20: ...ing fog button lasting 2 hours SELF SHUTOFF OF DEVICE circa 2 hours 17 minutes after last pressing fog button HEAT UP TIME max 30 seconds for cold device max 6 sec in energy saving mode FOGGING AGENT...

Page 21: ...lemente S 5 6 GEBRAUCHSANWEISUNG A Systembeschreibung S 21 B Ger tevorbereitung S 22 C Inbetriebnahme S 24 D Wartung und Pflege S 27 E Lagerung und Transport S 30 F Sicherheitshinweise S 30 G Optional...

Page 22: ...nden Spar sowie danach in einen sog Schlafmodus und bei l ngerem Nichtgebrauch sogar selbstst ndig aus Auf diese Weise wird die Batteriekapazit t geschont das Ger t bleibt l nger betriebsf hig und auc...

Page 23: ...bef llt und entl ftet um eine erste Erprobung zu erm glichen a Dazu Nebelfluid Dose senkrecht auf eine Unterlage stellen Ventilschutzkappe abnehmen und Dose mit einer Hand festhalten Eine Bef llung is...

Page 24: ...l LED blinkt zun chst und leuchtet sp ter permanent auf Siehe dazu Abschnitt D Wartung und Pflege Auf diese Weise erkennt der Anwender recht fr h dass ein Nachladen der Batterie bevor steht er kann so...

Page 25: ...warzen Kunststoffringes versehen Durch seitliches Verdrehen des Ringes k nnen die sechs Luftzuf hr ffnungen im Applikator verkleinert oder ganz verschlossen werden was deutliche Auswirkung auf den Neb...

Page 26: ...r eine m glichst lange Batterienutzungsdauer ist das SAFEX FlowMarker Modell II jetzt mit einem ENERGIE SPARMODUS ausger stet Wird nach Aktivierung der Ger teheizung innerhalb von ca 2 Minuten kein Ne...

Page 27: ...orgenommen kann aber auch an vorhandenen Ger ten nachger stet werden z B auch von Service Stationen Insbesondere f r station re aber auch f r mobile Anwendungen kann es sinnvoll sein den SAFEX FlowMar...

Page 28: ...TUNG UND PFLEGE D Gelegentlich kann sich nach l ngerem Nichtgebrauch der Tankkolben des FlowMar ker festsetzen Dies ist jedoch kein wirklicher Defekt sondern kann einfach behoben werden indem man mit...

Page 29: ...wechsel der LED am Ladeger t angezeigt Im Ger tetank befindliche Nebelfluide k nnen ohne Beeintr chtigung bis zu 2 Jahren im Ger t verbleiben Auch die SAFEX NEBELFLUID Druckgaspackung ist mindestens 2...

Page 30: ...Dose steht jedoch unter Gasdruck und ist daher als Gefahrgut im Sinne internationaler Transportvorschriften als UN Nr 1950 DRUCKGASPACKUNG erstickend Klasse 2 Kat 5A anzusehen Das Druckgas ist unbrenn...

Page 31: ...rden bevor es zur ck auf das Ger t montiert wird E LAGERUNG UND TRANSPORT Wird das Ger t l nger als 3 Monate nicht ben tigt und soll es nicht w hrend der Lagerung mit dem Netzteil verbunden bleiben so...

Page 32: ...in k nnen In Zweifelsf llen Bat terie aus dem Ger t entnehmen und dieses zur Reparatur einsenden 4 Unsachgem e Reparaturen bzw Ver nderungen der Regeleinrichtungen k nnen zu Gefahren und zur Zerst run...

Page 33: ...eingeschoben Die Ringe nehmen eventuell austretendes Kondensat auf m ssen jedoch bei intensiverem Gebrauch des Ger tes regelm ig erneuert werden Die SAFEX NEBELFLUID Druckgaspackung steht unter Druck...

Page 34: ...Die folgenden FlowMarker FERNSTEUERUNGEN k nnen so angeschlossen werden FlowMarker Kabelfernsteuerung 10 m einfache jedoch robuste Kabelfernsteuerung mit hochflexiblen d nnem Kabel mit dem durch Knop...

Page 35: ...ebeltasters 2 h andauernd GER TE SELBSTABSCHALTUNG circa 2 h und 17 min nach letzter Bet tigung des Nebeltasters AUFHEIZZEIT max 30 Sek bei kaltem Ger t BETRIEBSSTOFF ausschlie lich SAFEX FlowMarker N...

Page 36: ......

Reviews: