SafanDarley E-Brake
Working
Instruction manual SafanDarley E-Brake Premium 100-3100 100Pr 2019
54
operating the foot pedal). Even when the light guard is interrupted during
return stroke, the system will take it to be the break.
Autoretour (See TS-manual) has to be on.
If the light guard is interrupted and left 1x the upper beam will move
downwards with high speed (approach speed).
At the mute point will be switched over to bending speed. At BDP the upper
beam will return to TDP.
The light guard may not be interrupted during the whole downwards-
movement of the upper beam.
Because the light guard is active as safeguard, the maximum closing speed
of the upper beam is allowed to be higher than 10 mm/s.
In this position the light guard is not active, in this position all the
movements (back gauge and upper beam) start when the foot pedal is
pressed.
The light guard may be interrupted during the whole movement of the
upper beam.
Because the light guard is not active as safeguard, the maximum closing
speed of the upper beam is not allowed to be higher than 10 mm/s.
In this position the light guard is only active as safeguard during the first
part of the stroke of the upper beam (as far as the mute point). At the
mute point the light guard will be switched off.
In this position all the movements of the back gauge and upper beam start
when the light guard is interrupted and left 1x. (When switched into One
break mode the X-axis should, at the first time, be set in position by
operating the foot pedal). Even when the light guard is interrupted during
return stroke, the system will take it to be the first brake.
If the light guard is interrupted and left 1x, the upper beam will move
downwards with high speed (approach speed).
Because the light guard is active as safeguard during this part of the stroke
of the upper beam, the maximum closing speed of the upper beam is
allowed to be higher than 10 mm/s.
The light guard may not be interrupted during this movement of the upper
beam.
At mute point the movement of the upper beam will stop and the light
guard will be switched off.
If the foot pedal is pressed, the movement downwards of the upper beam
will start again, but the speed is low now.
The light guard may be interrupted during this part of the movement.
Because the light guard is not active as safeguard during this part of the
stroke of the upper beam, the maximum closing speed is not allowed to be
higher than 10 mm/s.