a) Menus du SETUP : a. groupe CYCLE /
SETUP menus : a. CYCLE group
MENU
AFF gauche
Left display
Afficheur droit
Right display
Mini Maxi
PAS
STEP
Défaut
Default
Unité
Unit
Accessibilité *(1)
Accessible *(1)
Commentaire
Comments
Temps du point /
Spot time
tPt 00.5
00.5 10.0 00.1
00.5
S
Si cycle point
In spot cycle
Temps de pré-gaz /
Pre-gas
time
PrG 00.2
00.0 10.0 00.1
00.2
S
Permanente
Permanently
Temps de Hot Start /
Hot Start time
tHSs
OFF ou 00.5
00.0 10.0 00.1
OFF
S
Si mode Synergie
Si cycle
≠
point
In Synergy mode
If cycle
≠
spot
Courant Hot Start (vitesse fil)/
Hot Start current (wire speed)
IHS 030
-70 +70 01
030
%
Si mode Synergie
Si cycle
≠
point
Si tHS
≠
0
In Synergy mode
If cycle
≠
spot
If tHS
≠
0
X% en
±
de vitesse fil
soudage
X% in
±
welding wire
speed
Tension Hot Start /
Hot Start voltage
UHS 000
-70 +70 01
000
%
Si mode Synergie
Si cycle
≠
point
Si tHS
≠
0
In Synergy mode
If cycle
≠
spot
If tHS
≠
0
X% en
±
de la tension
d’arc de hot start
X% in
±
hot start arc
voltage
Temps d’évanouissement /
Slope-down time
DdSt
OFF ou 00.5
00.0 05.0 00.1
OFF
S
Si mode Synergie
Si cycle
≠
point
In Synergy mode
If cycle
≠
spot
Courant évanouis (vitesse fil)/
Current slope-down (wire
speed)
DdSI -30
-70 0 01 -30 %
Si mode Synergie
Si cycle
≠
point
Si dSt
≠
0
In Synergy mode
If cycle
≠
spot
If dSt
≠
0
X% en
±
de vitesse fil
soudage
X% in
±
welding wire
speed
Tension évanouis /
Voltage slope-down
DdSU 000
-70 +70 01
000
%
Si mode Synergie
Si cycle
≠
point
Si dSt
≠
0
In Synergy mode
If cycle
≠
spot
If dSt
≠
0
X% en
±
de la tension
d’arc d’évanouissement
X%
±
in arc slope-down
voltage
Temps anti-collage /
Anti-stick time
Pr_ 0.10
0.00 0.20 0.01
0.05
S
Permanente
Permanently
Activation Pr-Spray /
Pr-Spray activation
PrS
yES ou no
no
Permanente
Permanently
Temps de post gaz /
Post-gas time
PoG 00.5s
00.0 10.0 00.5
00.5
S
Permanente
Permanently
Réglage fin /
Fine setting
dYn ou rFP
000
-10 +10 01
000
Permanente
Permanently
Temps de Hot Start en
Electrode Enrobée /
Hot Start
time in Coated Electrode
mode
tHSs
OFF ou 00.5
00.0 10.0 00.1
OFF
S
Si mode MMA
In MMA mode
Courant Hot Start en
Electrode Enrobée /
Hot Start current in Coated
Electrode mode
IHS 030
000 060 001
030
%
Si mode MMA
Si tHS ‘MMA’
≠
0
In MMA mode
If 'MMA' tHS
≠
0
X% en + de la consigne
courant soudage
% in + welding current
setpoint
Temps Séquenceur /
Sequencer time
TtSE
OFF ou 00.5
000 05.0 00.1
OFF
S
Si mode Synergie
Si cycle
≠
point
In Synergy mode
If cycle
≠
spot
Intensité Séquenceur /
Sequencer current
ISE 030
-50 50 01
30
%
Si mode Synergie
Si cycle
≠
point
Si tSE
≠
0
In Synergy mode
If cycle
≠
spot
If tSE
≠
0
X% en
±
de la consigne
courant soudage
X% in + welding current
setpoint
Si le procédé MMA (électrode enrobé) est sélectionné seuls les MENUS ‘FAC’ ‘tHS’ et ‘IHS’
pour MMA sont accessibles
If the MMA process (coated electrode) is selected only the menus ‘FAC’ ‘tHS’ and ‘IHS’ for
MMA are accessible