Programme table
(diagnosis menu)
Function/Standard
Setting range
Increment
Comments
EXPRESSO
No. of PULSES 195
50 – 1,000 Pulses
+/- 1
COFFEE
No. of PULSES 360
50 – 1,000 Pulses
+/- 1
Number of flow meter pulses for
each saved cup fill volume, where
300 pulses correspond to approx.
100 ml.
----HEATING----
PARAMETER K1 8
1 – 50
+/- 1
Do not change!
----HEATING----
PARAMETER K2 30
1 – 50
+/- 1
Do not change!
NORMAL TEMP.
° C 90
70- 130°C
+/- 1
Normal temperature is used if not
more than 6 min. have elapsed
since last coffee dispensed.
HIGH TEMP.
° C 111
70- 130°C
+/- 1
If no coffee is dispensed for an
extended time (over 6 min.), the
next coffee will be heated to a
higher temperature to compensate
for cooling of the brewing unit
and the associated temperature
loss.
TEMP. OF 1st
COFFEE
° C 118
70- 130°C
+/- 1
Used when dispensing the first
coffee after the machine has been
turned on, to compensate for the
high temperature loss due to the
cold brewing unit and water pipes.
STEAM
25
20- 50
+/-1
Pump pulse during steam
dispensing
The higher the value, the more
pulses but more humid is the
steam.
TEMP. INCREASE
° C 10
0-50°C
+/-1
The boiler temperature is
increased by a set value shortly
before brewing in order to pre-
heat the boiler and compensate
for the temperature drop during
the first water flow.
Summary of Contents for RI9722/11
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ......
Page 16: ......
Page 38: ......
Page 40: ......
Page 50: ......
Page 52: ......
Page 71: ...Saeco International Group REV 1 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 72: ......
Page 74: ......
Page 78: ......
Page 108: ......
Page 109: ...Saeco International Group REV 1 FEB 2005 CHAPTER 9 CIRCUIT DIAGRAMS ...
Page 110: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 124: ......
Page 126: ......
Page 144: ......
Page 158: ......
Page 160: ......
Page 172: ......
Page 173: ...Saeco International Group REV5 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 174: ......
Page 178: ......
Page 180: ......
Page 188: ......
Page 190: ......
Page 222: ......
Page 223: ...Saeco International Group REV5 FEB 2005 CHAPTER 10 CIRCUIT DIAGRAMS ...
Page 224: ......