1. Water system
1.1. Water system
(Incanto, Easy)
(Incanto Easy with boiler J)
Component
Function
1
Water tank
Water supply
2
Float
Water level monitoring
3
Water filter
Water cleaned of solid matter
4
Flow meter (turbine)
Measure flow rate
5
Pump
Water flow/Pressure build-up
(13 to15 bar)
6
Safety valve
Protect boiler against overpressure (opens at 17 bar)
7
Instantaneous water
heater
Heats water to approx. 94
°
C
(for brewing process)
8
Sensor (KTY)
Transmits current temperature value to electronic
system
9
Thermostat
Interrupts complete flow supply if overheating.
10
Boiler pin (Valve plug)
Opens when brewing unit is aligned with water circuit
to the unit itself.
11
HWS valve
For hot water and steam dispensing
Float
Flow meter
Pump
Safety valve
Overpressure
Thermal sensor
Thermostat
Boiler pin
HWS
valve
To brewing unit
Water / steam
Boiler
Water tank
Water filter
Heating
1000W
Summary of Contents for RI9722/11
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ......
Page 16: ......
Page 38: ......
Page 40: ......
Page 50: ......
Page 52: ......
Page 71: ...Saeco International Group REV 1 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 72: ......
Page 74: ......
Page 78: ......
Page 108: ......
Page 109: ...Saeco International Group REV 1 FEB 2005 CHAPTER 9 CIRCUIT DIAGRAMS ...
Page 110: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 124: ......
Page 126: ......
Page 144: ......
Page 158: ......
Page 160: ......
Page 172: ......
Page 173: ...Saeco International Group REV5 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 174: ......
Page 178: ......
Page 180: ......
Page 188: ......
Page 190: ......
Page 222: ......
Page 223: ...Saeco International Group REV5 FEB 2005 CHAPTER 10 CIRCUIT DIAGRAMS ...
Page 224: ......