Function/Standard
Setting range
Increment
Comments
WATER DESCALING
(ml)
Total water flow (in ml) since last
descaling / resettable.
HOT WATER
FLOW (l/h) 20
6 - 34 1/h
+/- 2 1/h
The pump delivery rate for hot
water can be expressed in litres
per hour.
HOT WATER
PUMP ADJUST. 63000
58,000 - 65,500
+/- 1
The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a
phase controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
WATER RESERVE
COUNTER
NUMBER
When the water tank is full, the
value from WATER RESERVE
STOP is applied. The flow meter
pulses are counted from when the
reed switch is switched and
deducted from the value. If a
beverage is chosen for which the
saved pulse number is higher than
the remaining pulses, the message
FILL WATER TANK appears.
WATER RESERVE
STOP 600
Water reserve from when the read
switch is switched to pulses.
MACHINE STATUS
36
0 - 255
Programme code
--DATE OF MANUF---
DAY
---------------------
---------------------
--
--DATE OF MANUF---
MONTH
---------------------
---------------------
--
--DATE OF MANUF---
YEAR
---------------------
---------------------
--
This date indicates when the
machine was manufactured. This
date cannot be changed.
--SERVICE DATE--
DAY
0 - 31
+/- 1
--SERVICE DATE--
MONTH
0 - 12
+/- 1
--SERVICE DATE--
YEAR
1996 - 2050
+/- 1
The service date indicates the date
of the machine's last service. This
date can be changed and must be
updated at each service.
Exit:
Switch the machine off at the main switch.
Summary of Contents for RI9722/11
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ......
Page 16: ......
Page 38: ......
Page 40: ......
Page 50: ......
Page 52: ......
Page 71: ...Saeco International Group REV 1 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 72: ......
Page 74: ......
Page 78: ......
Page 108: ......
Page 109: ...Saeco International Group REV 1 FEB 2005 CHAPTER 9 CIRCUIT DIAGRAMS ...
Page 110: ......
Page 112: ......
Page 114: ......
Page 116: ......
Page 120: ......
Page 124: ......
Page 126: ......
Page 144: ......
Page 158: ......
Page 160: ......
Page 172: ......
Page 173: ...Saeco International Group REV5 FEB 2005 CHAPTER 6 FAULTS Page 1 Faults 1 ...
Page 174: ......
Page 178: ......
Page 180: ......
Page 188: ......
Page 190: ......
Page 222: ......
Page 223: ...Saeco International Group REV5 FEB 2005 CHAPTER 10 CIRCUIT DIAGRAMS ...
Page 224: ......