INCANTO 02 TECHNICAL SPECIFICATIONS
4/6
How to measure the milk cream.
The temperature (Trefr or Tamb) of the milk doesn’t affect as much the test result on measuring
the milk cream; by convection is assumed to always use milk at refrigerator temperature
T
refr..
Manual systems (Pannarello)
Pour 100cc. of milk at Trefr. in a beaker of 250 ml of capacity and with a inner diameter of 70 mm;
with machine in steam mode:
1.
Open the steam knob to discharger water circuit for 4 sec, then close the knob.
2.
Place the beaker with the frother dipped in milk, open the steam knob to maximum and
start the chronometer.
3.
After about 30 to 60 seconds, close the knob and check the result on milk.
Semi-automatic systems (cappuccino)
Pours milk at Trefr. in a container ; with the machine in steam mode:
1.
Open the steam knob to discharge water circuit for 4 sec. then close the knob.
2.
Insert the silicone tube in the milk container, placing a beaker of 250 ml capacity and with
an inner diameter of 70 mm under the cappuccino maker and open the steam knob.
3.
After having provided 100gr. of product, close the knob and check the result obtained on
milk. Note: The same applies to machines which have a steam key on the user interface
and a solenoid valve in place of the steam tap.
Automatic: Carafe, Cappuccino Pinless wonder (New Royal, Energica Pure, Intelia EVO
Latte), etc..
After setting the machine to delivery of 100gr. of product:
1.
Launch the “hot milk” function.
2.
Collect the product in a beaker with a 250ml of capacity and with an inner diameter of
70 mm, and verify the result obtained on milk. Carry out the test using milk at a
T
refr..
In case the machine allows modify of the emulsion through the menu, use the machine with the
emulsion set to the default value.
Related to the above testing procedure derives the following table of acceptability:
Manual, Semi-Automatic and Automatic’s Milk System
Grams of Product
Minimun Height of the milk cream
≥ 130
≥ 30mm
120
≥ 25mm
110
≥ 22mm
100
≥ 20mm
90
≥ 16mm
80
≥ 13mm
70
≥ 11mm
NB:
To verify more accurately the height of the cream, a practical expedient dictated by expe
-
rience is to add to the product just delivered a small amount of coffee. The addition of coffee
immediately put in evidence the surface of separation between liquid and cream.
Summary of Contents for OTC SERIES
Page 3: ...INCANTO CHAPTER 1 INTRODUCTION...
Page 11: ...INCANTO CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 18: ...INCANTO CHAPTER 3 BRIEF INSTRUCTIONS...
Page 22: ...INCANTO CHAPTER 4 OPERATING LOGIC...
Page 33: ...INCANTO CHAPTER 5 SERVICE MODE...
Page 44: ...INCANTO CHAPTER 6 SERVICE AND MAINTENANCE...
Page 47: ...INCANTO CHAPTER 7 DISASSEMBLY...
Page 57: ...INCANTO CHAPTER 8 NOTES...
Page 58: ...INCANTO 08 NOTES 1 1...
Page 59: ...INCANTO CHAPTER 9 WATER CIRCUIT DIAGRAM...