INCANTO 04 OPERATING LOGIC
5/10
When the coffee grinder is working, the software monitors the current consumption. If the current
value is very low, the machine concludes that coffee is missing; if the current value is very high, the
machine concludes that the coffee grinder is blocked; instead, if the current value is in the middle,
the machine concludes that all is ok and it goes on to do the product.
Because the current consumption of grinder changes depending on the situations (motor new or
old, cold or hot, etc., coffee blends), these current thresholds are not static, but dynamic.
1) When the system get the stability (i.e. the system got the current target) the coffee doses
should be:
A1
A2/3
A4/5
7,5 9,0 10 ±1,5 grams
with medium grinding (500±60μm) and using coffee of test.
2) the 3 grinding times are always:
T
1
<T
2
<T
3
beside, every grinding time is, respectively:
4,0s ≤
T
3
≤10s (10000ms)
3,5s ≤
T
2
≤9s (9000ms)
3,0s ≤
T
1
≤8,1s (8100ms)
4.5.2. Coffee lack detection and coffee grinder blocked
DOSE ADJUSTMENT
5 levels
Grinder
Time
Min
Grinder
Time
Max
Grinder
Time
Curret target
Aroma
of the
grinded
product
Aroma1
Very Light
T
1
3s
8,1s
I
0 +
55mA
Aroma2
Light
T
2
3,5s
9s
I
0 +
100mA
Aroma3
Med
Aroma4
Strong
T
3
4s
10s
I
0 +
200mA
Aroma5
Very Strong
Summary of Contents for OTC SERIES
Page 3: ...INCANTO CHAPTER 1 INTRODUCTION...
Page 11: ...INCANTO CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 18: ...INCANTO CHAPTER 3 BRIEF INSTRUCTIONS...
Page 22: ...INCANTO CHAPTER 4 OPERATING LOGIC...
Page 33: ...INCANTO CHAPTER 5 SERVICE MODE...
Page 44: ...INCANTO CHAPTER 6 SERVICE AND MAINTENANCE...
Page 47: ...INCANTO CHAPTER 7 DISASSEMBLY...
Page 57: ...INCANTO CHAPTER 8 NOTES...
Page 58: ...INCANTO 08 NOTES 1 1...
Page 59: ...INCANTO CHAPTER 9 WATER CIRCUIT DIAGRAM...