INCANTO
03 BRIEF INSTRUCTIONS
3/3
The machine is out of service
If the machine error alarm signal is triggered, the error code is
displayed in the bottom right corner of the display.
XX
Red Display
Error
code
Behaviour
Cause
Action
1
Coffee grinder
blocked
Coffee outlet duct
clogged
Clean the coffee outlet duct thoroughly.
3 - 4
Brew group locked,
cannot be taken out
The brew group is
incorrectly positio
-
ned.
Close the service door. Turn the machine off
and back on again. Wait for the ‘Ready for
brewing’ signal and then remove the brew
group.
5
Water circuit error
Air in the water
circuit
Remove and restore the water tank a couple
of times, making sure to position it correctly.
Check that the water tank seat is clean.
3.2. Operation, cleaning and maintenance
Operating the machine
1
Fill water tank
2
Fill the coffee bean hop-
per
3
Switch on the appliance
4
Press the button to start
the appliance
5
Heating
When the heating phase begins, wait for it to finish
6
Rinse
Carry out a rinse cycle for the internal circuits
7
Machine ready
The machine is ready to dispense beverages
CLEANING AND TECHNICAL SERVICING
A
Empty the dregs drawer
When indicated
B
Empty the drip tray
As necessary
C
Clean the water tank
Weekly
D
Clean the coffee bean hopper
As necessary
E
Clean the casing
As necessary
F
Clean the brewing unit
Every time the coffee bean hopper is filled or weekly
Lubricate the brewing unit
After 500 dispensing cycles or when the grease is
no longer present on the brewing unit
Clean the unit housing
Weekly
H
Descaling
When indicated
Summary of Contents for OTC SERIES
Page 3: ...INCANTO CHAPTER 1 INTRODUCTION...
Page 11: ...INCANTO CHAPTER 2 TECHNICAL SPECIFICATIONS...
Page 18: ...INCANTO CHAPTER 3 BRIEF INSTRUCTIONS...
Page 22: ...INCANTO CHAPTER 4 OPERATING LOGIC...
Page 33: ...INCANTO CHAPTER 5 SERVICE MODE...
Page 44: ...INCANTO CHAPTER 6 SERVICE AND MAINTENANCE...
Page 47: ...INCANTO CHAPTER 7 DISASSEMBLY...
Page 57: ...INCANTO CHAPTER 8 NOTES...
Page 58: ...INCANTO 08 NOTES 1 1...
Page 59: ...INCANTO CHAPTER 9 WATER CIRCUIT DIAGRAM...