STORING THE TRANSFER PUMP

Store indoors in a dry, locked-up place out of the reach of 
children, with the battery pack removed and power supply 
disconnected. Keep away from corrosive agents such as 
garden chemi cals and de-icing salts. 

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most 
plastics are susceptible to damage from various types of 
commercial solvents and may be damaged by their use. Use 
clean cloths to remove dirt, dust, oil, grease, etc.
After extended use, disconnect the battery pack and flush 
the pump from the inlet side with fresh clean water. This pre-
vents any build up of solid deposits on the pump’s internal 
water sensors.

MAINTENANCE

REPLACING THE IMPELLER AND O-RING

See Figures 8 - 9.

  Remove battery pack or disconnect pump from power 

source.

  Locate and remove the four screws from the impeller 

plate cover.

  Carefully remove impeller cover plate and inspect o-ring 

for damage or wear. If o-ring is damaged or worn, replace 
o-ring.

 

NOTE:

 Be sure to keep the pump cover, plastic window, 

and glass plate together in the same order for installation.

  Remove old impeller and replace with new, lining up the 

key, and insert into the pump as far as it will go.

  Apply a small amount of silicone grease to the impeller 

vanes for best performance.

  Make sure o-ring is properly seated and replace impeller 

cover plate, plastic window, and glass plate.

  Replace the four screws and hand tighten only. Refer 

to 

Starting/Stopping the Transfer Pump

 and check to 

make sure the impeller plate does not leak.

STARTING/STOPPING THE TRANSFER PUMP

See Figures 5 - 7.

  WARNING:

Battery tools are always in operating condition, therefore 
the unit should always be in the OFF position, with the 
battery pack removed, when not in use. Do not leave unit 
on while unattended. Failure to follow these instructions 
could result in serious personal injury.

  Add water or a small amount of silicone based pump oil 

to the water inlet side of the pump to prime the impeller.

NOTE:

 For best results, add water to the inlet to prime 

the pump. This step is necessary to improve the priming 
reliability.

  Insert the battery.

  Make sure the inlet hose and filter are attached. See 

As-

semble Intake Filter and Hose

 in 

Assembly

.

NOTE: 

Do not turn pump on without both intake and 

outlet hoses securely connected.

  To start the pump, depress the ON/OFF button.

NOTE:

 The pump has internal protection functions built 

in to it. The LED will flash if an error is detected.  Please 
refer to the 

Troubleshooting

 guide later in this manual for 

possible issues and solutions.

  To stop the pump, depress the ON/OFF button a second 

time.

USING THE SPEED AND TIMER FEATURE

See Figure 5.

SELECTING THE SPEED

  Depress the ON/OFF button to start the pump.

  Depress the speed button.

NOTE:

 With each press the speed and flow of the pump 

will change from LOW to MED to HIGH.

  The selected running speed is indicated by the corre-

sponding LED.

SELECTING THE RUN TIME

  Depress the ON/OFF button to start the pump.

  Depress the timer button.

NOTE:

 After pressing the timer button once, the pump 

will run for 5 minutes. With each additional press, the 
running time of the pump increases by 5 minutes for up 
to 15 minutes.

  The selected running time is indicated by the correspond-

ing LED.

  After the preset time has elapsed, the pump will turn off 

automatically.

  To switch the timer function OFF, press the timer button 

until the timer indicator lights go out.

Summary of Contents for RY20WP18BTL

Page 1: ...eguridad importantes 2 3 Advertencias de seguridad para bomba para transferir 3 S mbolos 4 Caracter sticas 5 Armado 5 Funcionamiento 6 7 Mantenimiento 7 Soluci n de problemas 8 Pedidos de piezas servi...

Page 2: ...ttery compartment compartiment piles compartimiento de bater a B Latch loquet pestillo C Battery pack bloc piles paquete de bater a D Battery port logements de bloc piles puertos de bater as D B C A F...

Page 3: ...lo B Cover plate plaque de recouvrement placa cobertora C Plastic window fen tre en plastique ventana de pl stico D Glass plate plaque de verre placa de vidrio E O ring joint torique juntas t ricas FI...

Page 4: ...al gasoline or petroleum products bleaches orindustrialgradesolutions Theseproducts cancausephysicalinjuriestotheoperatorandirreversible damage to the pump Do not use product if switch does not turn i...

Page 5: ...njury Do not charge battery tool in a damp or wet location Donotuse store orchargebatterypacksorproducts in locations where the temperature is less than 50 F or more than 100 F Do not store outside or...

Page 6: ...ay prohibit disposal of batteries in ordinary trash Consult your local waste authorityforinformationregardingavailablerecyclingand ordisposaloptions V Volts Voltage Hz Hertz Frequency cycles per secon...

Page 7: ...perly assembled could result in serious personal injury If any parts are damaged or missing please call 1 800 776 5191 for assistance WARNING If any parts are damaged or missing do not operate this pr...

Page 8: ...are assembling parts making adjustments cleaning or when not in use Removing battery pack will prevent accidental starting that could cause serious personal injury To install Openthebatterycoverbyrel...

Page 9: ...t leak STARTING STOPPING THE TRANSFER PUMP See Figures 5 7 WARNING Battery tools are always in operating condition therefore the unit should always be in the OFF position with the battery pack removed...

Page 10: ...ry pump shutdown Locked impeller Battery is discharged Check the viewing window Make sure there is water in the pump Turn off pump and then turn on to reset Avoid letting the pump run dry Clear any bl...

Page 11: ...ION Cette pompe a t test e pour tre utilis e seulementavecdel eau Nepasutiliseraveclesproduits suivants essence produits p troliers javellisants solvants ou solutions acides alcalines inflammables ou...

Page 12: ...l fonctionnant sur piles dans un endroit humide ou mouill Ne pas utiliser remiser ou charger le bloc piles ou produits dans des emplacements o la temp rature est inf rieure 10 C 50 F ou sup rieure 38...

Page 13: ...vernementales peuvent interdire de jeter les piles dans les ordures m nag res Consulter les autorit s locales comp tentes pour les options de recyclage et ou l limination V Volts Tension Hz Hertz Fr q...

Page 14: ...l impulseur NOTE Pour de meilleurs r sultats ajouter de l eau dans l orifice d entr e pour amorcer la pompe Cette tape est n cessaire pour am liorer la fiabilit de l amor age Fixer le tuyau d admissio...

Page 15: ...uetetenouvrant le couvercle Mettrelebloc pilesdanslecompartimentdespilesetins rer le pile dans le produit comme il est indiqu AVERTISSEMENT S assurer que les loquets au bas du bloc piles s enclenche e...

Page 16: ...terlasectionMiseenmarche et arr t pompe de transfert et s assurer qu aucune fuite ne se d clare au niveau du couvercle de l impulseur NOTE Pour de meilleurs r sultats ajouter de l eau dans l orifice d...

Page 17: ...g e V rifier la fen tre de visualisation S assurer qu il y a de l eau dans la pompe teindre la pompe puis la rallumer pour r initialiser viter de laisser la pompe tourner sec liminer tout blocage de l...

Page 18: ...ruptor puesto propicia accidentes BOMBA PARA TRANSFERIR USO Y CUIDADO PRECAUCI N La bomba ha sido evaluada para su uso con agua nicamente No la use con cidos alcalinos solventes material inflamable ga...

Page 19: ...ue incendios explosiones o riesgo de lesiones No cargue herramientas de bater as en lugares mojados o h medos No lo utilice guarde o cargue la paquete de bater as o la unidad en lugares donde la tempe...

Page 20: ...icipales estatalesofederalesproh bandesecharlasbater asenlabasuranormal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y dese...

Page 21: ...ara obtener los mejores resultados agregue agua en la entrada para cebar la bomba Este paso es necesario para mejorar la fiabilidad del cebado Conecte la manguera de entrada en el filtro de entrada Co...

Page 22: ...e y introduzca el paquete de bater as en el recept culo para bater as ADVERTENCIA Aseg rese de que las trabas del paquete de bater as quede insertada en su lugar y que el paquete de bater as est total...

Page 23: ...paraasegurarse de que la placa del impulsor no presente fugas Agregue agua o una peque a cantidad de aceite de bomba a base de silicona no incluido al lado de la entrada de agua de la bomba para cebar...

Page 24: ...La bomba seca est apagada Impulsor bloqueado La bater a est descargada Esp e por la ventana de visualizaci n Aseg rese de que haya agua en la bomba Apague la bomba y luego enci ndala para reiniciarla...

Page 25: ...NOTES NOTAS...

Page 26: ...e fournies lors d un appel de demande de service COMMENT OBTENIR LES PI CES DE REMPLACEMENT Les pi ces de remplacement peuvent tre achet es en ligne sur le site www ryobitools com ou par t l phone au...

Reviews: