TROUBLESHOOTING

WARNING:

With the battery pack removed from the misting fan, 
always clean and thoroughly dry out all parts of the 
misting fan, intake tube, and buckets when not in use 
to prevent the possible formation of bacteria or mold. 
Spraying mist that contains bacterial or mold can result 
in serious personal injury or illness.

NOZZLE MAINTENANCE

See Figure 7, page 10.

WARNING:

Ensure all nozzle maintenance is properly performed 
to prevent leaks. Leaks can result in a slippery surface, 
create a slip and fall hazard, or cause property damage.

Irregular mist patterns or leakage may be the result of a 
clogged or dirty nozzle. 

PROBLEM

POSSIBLE CAUSE

SOLUTION

Leak at nozzle or threaded hole

Nozzles were installed improperly.
Nozzles clogged or dirty.

Reinstall nozzles and tighten securely.
Clean nozzles.

Fan will not start

Battery is defective or fully discharged.

Charge battery or contact customer 
service.

To order these accessories, call 1-800-525-2579. 

 

Brass Nozzle ........................................................................................................................................ Model No. PMC080

 

Inline Misting Filter .............................................................................................................................Model No. PMCF009

 

Nozzle Cleaner .................................................................................................................................. Model No. PMCC008

WARNING:

Current attachments and accessories available for use with this product are listed above. Do not use any attachments 
or accessories not recommended by the manufacturer of this product. The use of attachments or accessories not 
recommended can result in serious personal injury.

ACCESSORIES

MAINTENANCE

To clean nozzles:

  Make sure both the power switch and pump switch are 

in the 

OFF  ( O )

 position.

  Remove the battery pack.

  Remove the brass nozzles from each side of the fan.

  Soak nozzles in nozzle cleaner (not included) to loosen 

foreign materials clogging or restricting the nozzle.

  Using a garden hose, flush debris out of nozzle by back 

flushing (running the water through the nozzle backwards 
or from the outside to the inside).

  Reconnect the nozzles.

FILTER MAINTENANCE

See Figure 8, page 10.

Periodically check the filter at the end of the intake tube for 
debris and to make sure it is in good condition. Remove the 
plastic filter cover and rinse or replace the filter, then snap 
the cover back together.

Summary of Contents for PMF01

Page 1: ...en comprendrelemanueld utilisationavant d employer ce produit GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS CONSERVER CE MANUEL POUR FUTURE R F RENCE TABLE OF CONTENTS Important Safety Instructions 2 3 Sy...

Page 2: ...USE AND CARE Use battery operated products only with specifically designated battery pack Use of any other batteries may create a risk of fire Use battery only with charger listed For use with 18V lit...

Page 3: ...t is severely damaged The batteries can explode in a fire To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device Not for use in kitchens For general...

Page 4: ...e in damp locations Long Hair Failure to keep long hair away from air inlet could result in personal injury Fan Blades Contact with moving fan blades can cause serious personal injury Recycle Symbol T...

Page 5: ...us personal injury WARNING Do not use this product to spray pesticides liquid fertilizers chemicals or any liquids other than clean water Spraying these substances could result in serious injury or il...

Page 6: ...d in the space provided on the unit NOTE The intake tube cannot be removed USING THE MISTING FAN WITH A GARDEN HOSE NOT INCLUDED See Figure 6 page 10 WARNING Always route hoses away from traffic areas...

Page 7: ...ntact customer service To order these accessories call 1 800 525 2579 Brass Nozzle Model No PMC080 Inline Misting Filter Model No PMCF009 Nozzle Cleaner Model No PMCC008 WARNING Current attachments an...

Page 8: ...une utilisation Ne jamais installer l appareil pr s des prises de courant ou des interrupteurs V rifier les tuyaux flexibles et les pi ces et s assurer qu ils ne sont pas endommag s Remplacer tout tuy...

Page 9: ...oit en pr sence d une flamme vive En explosant une pile peut projeter des d bris et des produits chimiques En cas d exposition rincer imm diatement les parties atteintes avec de l eau Ne pas recharger...

Page 10: ...util la pluie ni l humidit Cheveux longs Ne pas garder les cheveux longs l cart de l entr e d air peut entra ner des blessures H lices de ventilateur Tout contact avec des h lices de ventilateur en mo...

Page 11: ...lectionner la ventilateur LOW appuyer sur I Pour s lectionner la ventilateur HIGH appuyer sur II Pour mettre le ventilateur OFF s lectionner la position du centre O INTERRUPTEUR LOW FAIBLE OFF ARR T...

Page 12: ...entilateur et la pompe se soient compl tement arr t s avant de soulever le ventilateur de la cuve Le tube d admission peut tre rang dans l espace r serv cette fin sur l appareil NOTE Il n est pas poss...

Page 13: ...loc piles est d fectueux ou faible Recharger le bloc piles ou consulter service la client le ENTRETIEN Une pulv risation irr guli re ou une fuite indique que la buse est obstru e ou sale Pour nettoyer...

Page 14: ...las conexiones est n firmes antes de operar la unidad Sea precavido cuando use la unidad cuando haya mucho viento El viento fuerte puede hacer que el producto rociado ingrese a cables o dispositivos...

Page 15: ...jados o h medos Con el cumplimiento de esta regla se reduce el riesgo de una descarga el ctrica En condiciones extremas de uso o temperatura las bater as pueden emanar l quido Si el l quido llega a to...

Page 16: ...en lugares h medos Cabello largo Si no mantiene el cabello largo lejos de la entrada de aire puede producirse lesiones Hojas del ventilador El contacto con las hojas m viles del ventilador puede prov...

Page 17: ...productos qu micos o l quidos que no sean agua potable Esparcir estas sustancias podr a producir lesiones serias al operador o a las personas presentes APLICACIONES Esta producto puede emplearse para...

Page 18: ...omba en la posici n de APAGADO O Permita que el ventilador y la bomba dejen de funcionar antes de elevar el ventilador fuera del cubo El tubo de entrada debe almacenarse en el espacio provisto en la u...

Page 19: ...ne poca carga o est descargada Cargue la bater a MANTENIMIENTO ADVERTENCIA No permita en ning n momento que fluidos para frenos gasolina productos a base de petr leo aceites penetrantes etc lleguen a...

Page 20: ...LE OFF arr t HIGH lev de pompe interruptor BAJA APAGADO ALTA de bomba C Intake tube tube d admission tubo de nebulizaci n A D Garden hose connector raccord du boyau d arrosage conector de la manguera...

Page 21: ...Intake tube tube d admission tubo de nebulizaci n PLACE FAN ON TOP OF 5 GALLON BUCKET D POSER LE VENTILATEUR SUR UN SEAU DE 18 9 L 5 GAL COLOQUE EL VENTILADOR EN LA PARTE SUPERIOR DE UN CUBO DE 18 9 L...

Page 22: ...bierta filtro B Filter filtre filtro A Brass nozzles buse en laiton boquillas de lat n A Fig 5 Fig 6 Fig 8 A Garden hose connector raccord du boyau d arrosage conector de la manguera de jard n B Garde...

Page 23: ...NOTES NOTAS...

Page 24: ...s required MODEL NUMBER _______________ SERIAL NUMBER ____________________________ Pour faire une demande de r parations ou obtenir des pi ces de rechange trouver un Centre de r parations agr pour obt...

Reviews: