AC power
Warning! Read ‘Safety information’ on page 4 before
connecting the fixture to AC mains power.
Warning! The mains power input cable supplied with the
fixture is rated 6 A and can supply only one fixture with
mains power. Do not connect any device to the fixture’s
MAINS OUT power throughput socket when using this
input cable. If you want to connect other fixtures to the
MAINS OUT socket, see ‘Linking fixtures to power in a
chain’ on page 13.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with
a fuse or circuit breaker and ground-fault (earth-fault)
protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixtures can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut
power, as this may cause arcing at the terminals that will damage the
connectors.
Do not use an external dimming system to supply power to the fixture, as this
may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard-wired to a building electrical installation if you want to
install it permanently, or if a cable with suitable power plug pre-installed is not
supplied, a power plug that is suitable for the local power outlets can be
installed on the power cable.
If you install a power plug on the supplied power cable, install a grounding
type (earthed) plug with integral cable grip that is rated minimum 250 V, 6 A.
Follow the plug manufacturer’s instructions and connect the wires in the
power cable as shown in this table:
Live or L
Neutral or N
Earth, Ground or
US system
Black White
Green
EU system
Brown Blue Yellow/green