Technical Specifications
RuggedRouter
®
RX1000 Family
47
RuggedCom
®
- Rev.122
5.7 Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
IEC 60068-2-1
Cold
Temperature
Test Ad
-40 deg. C, 16 Hours
N/A
IEC 60068-2-2
Dry Heat
Test Bd
+85 deg. C, 16 Hours
N/A
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 deg C, 6 cycles
N/A
IEC 60255-21-1
Vibration
2g @ (10-150) Hz
Class 2
IEC 60255-21-2
Shock
30g @ 11ms
Class 2
Table 27: Environmental Type Tests
5.8 Operating Environment
Parameter
Range
Comments
Ambient Operating
Temperature
-40 to 85
C
Ambient Temperature as
measured from a 30cm
radius surrounding the
center of the enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage
Temperature
-40 to 85
C
Table 28: Operating Environment
5.9 Agency Approvals
Agency
Standards
Comments
CSA
CSA C22.2 No. 60950, UL 60950
Passed
CE
EN 60950, EN 61000-6-2
CE Compliance is
claimed via Declaration
of Self Conformity Route
FCC
FCC Part 15, Class A
Passed
CISPR
EN55022, Class A
Passed
FDA/CDRH
21 CFR Chapter 1, Subchapter J
Passed
IEC/EN
EN60825-1:1994 + A11:1996 + A2:2001
Passed
Table 29: Agency Approvals