Technical Specifications
RuggedRouter
®
RX1000 Family
45
RuggedCom
®
- Rev.122
5.5 IEC 61850-3 Type Tests
Test
Description
Test Levels
Severity
Levels
IEC 61000-4-2
ESD
Enclosure Contact
+/- 8kV
4
Enclosure Air
+/- 15kV
4
IEC 61000-4-3
Radiated RFI
Enclosure ports
20 V/m
x
IEC 61000-4-4
Burst (Fast
Transient)
Signal ports
+/- 4kV @ 2.5kHz
x
D.C. Power ports
+/- 4kV
4
A.C. Power ports
+/- 4kV
4
Earth ground ports
+/- 4kV
4
IEC 61000-4-5
Surge
Signal ports
+/- 4kV line-to-earth,
+/- 2kV line-to-line
4
D.C. Power ports
+/- 2kV line-to-earth,
+/- 1kV line-to-line
3
A.C. Power ports
+/- 4kV line-to-earth,
+/- 2kV line-to-line
4
IEC 61000-4-6
Induced
(Conducted)
RFI
Signal ports
10V
3
D.C Power ports
10V
3
A.C. Power ports
10V
3
Earth ground ports
10V
3
IEC 61000-4-8
Magnetic Field
Enclosure ports
40 A/m continuous,
1000 A/m for 1 s
N/A
IEC 61000-4-29
Voltage Dips &
Interrupts
D.C. Power ports
30% for 0.1s, 60% for 0.1s,
100% for 0.05s
N/A
A.C. Power ports
30% for 1 period,
60% for 50 periods
N/A
IEC 61000-4-11
100% for 5 periods,
100% for 50 periods
2
N/A
IEC 61000-4-12
Damped
Oscillatory
Signal ports
2.5kV common,
1kV differential mode @ 1MHz
3
D.C. Power ports
2.5kV common,
1kV differential mode @ 1MHz
3
A.C. Power ports
2.5kV common,
1kV differential mode @ 1MHz
3
IEC 61000-4-16
Mains
Frequency
Voltage
Signal ports
30V Continuous, 300V for 1s
4
D.C. Power ports
30V Continuous, 300V for 1s
4
IEC 61000-4-17
Ripple on D.C.
Power Supply
D.C. Power ports
10%
3
IEC 60255-5
Dielectric
Strength
Signal ports
2kVac (Fail-Safe Relay output)
N/A
D.C. Power ports
1.5kV DC
N/A
A.C. Power ports
2kV AC
N/A
IEC 60255-5
H.V. Impulse
Signal ports
5kV (Fail-Safe Relay output)
N/A
D.C. Power ports
5kV
N/A
A.C. Power ports
5kV
N/A
Table 25: IEC 61850-3 Type Tests