Installation
RuggedCom
®
- Rev.122
22
RuggedRouter
®
RX1000 Family
3.2.5 Dielectric Strength Testing
For dielectric strength (HIPOT) testing in the field, users must remove the metal
jumper located on terminal 2, 4, and 6 of the power supply terminal block. This metal
jumper connects transient suppression circuitry to chassis ground and must be
removed in order to avoid damage to transient suppression circuitry during HIPOT
testing. Figure 15 shows the proper HIPOT test connections and should be followed
to avoid damage to the device.
Figure 15: Dielectric Strength (HIPOT) Testing