CLASSIC-LINE
ECO-LINE
Installation Guide
33
≥ 5 cm
X
Radiation area
In front of the fireplace door, you have
to respect a distance of
X cm
towards
any combustible building material. If a
both sides areated protection wall is
built,
X/2
cm is then sufficiant.
A minimum distance of
5 cm
towards
combustible building materials is to be
respected from the side elements of the
heating installation.
This distance must be exposed to an air
stream, that no heat congestion can ap-
pear.
X
[cm]
X
[cm]
Axinit Front S
170
Prisma V/S/K
80
Ellipse V/S/K
80
Prismalo 500 V/S/K
80
Jade Front S/K
80
Saphir Front S/K
80
Jade Tunnel S/K
80
Saphir Tunnel S/K
80
Larimar Front S
160
Saphir Giant S/K
80
Lumo S/K
80
Saphir Giant 500 S/K
80
Pi Classic V/S
100
720 Compact K
160
Pi Compact V/S
100
720 V/S/K (ECO)
80
Pi-ccolo Classic V/S
80
720 Giant V/S/K
80
Pi-ccolo Compact V/S
80